Purpose: Brachytherapy (BT) after surgical resection of keloids reduces the risk of local recurrence, but standardization of dose/technique is lacking. Typical keloid BT treatment utilizes a single-channel source prescribed to 5-mm depth. We investigated the dosimetry of a volume-based target definition for interstitial high-dose-rate BT treatment of keloids.

Methods And Materials: We retrospectively identified consecutive 14 patients who had a total of 20 keloids treated with interstitial high-dose-rate BT for keloids at our institution between 2004 and 2014. Keloids were treated with a single 8 Gy fraction prescribed to 5 mm beneath the scar within 36 h of surgery. Retrospectively, a 3-mm skin high-risk clinical target volume (HR-CTV) was contoured under the scar for volume-based dose calculations.

Results: Mean (SD) HR-CTV was 3.91 cm (3.1) and mean (SD) HR-CTV dose was 11.3 Gy (3.6). Mean D (SD) was 62.9% (25.8) and mean V (SD) was 56.5% (26.4). The mean V (SD), V (SD), and V (SD) were as follows: 37.6% (19.9), 25.1% (14.4), and 11.3% (6.5), respectively. No local failures were reported at 9 months median followup. There were no Grade 2 or higher late toxicities.

Conclusions: Using a volume-based target definition, a wide range of target coverage was observed. This is likely a consequence of the curvature of the skin and the challenges of keeping the catheter equidistant from the skin across the target. Additional data are needed to define the potential clinical impact on outcomes/toxicities of dosimetric correlates with single-catheter BT keloid treatment.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.brachy.2020.07.008DOI Listing

Publication Analysis

Top Keywords

interstitial high-dose-rate
12
keloid treatment
8
volume-based target
8
target definition
8
keloids treated
8
keloids
5
target
5
high-dose-rate brachytherapy
4
treatment
4
brachytherapy treatment
4

Similar Publications

Purpose: To compare the clinical outcomes of two different schedules of modern image-guided adaptive brachytherapy (IGABT) in patients underwent chemoradiotherapy (CCRT) and high-dose rate (HDR) brachytherapy (BT) for locally advanced cervical cancer treated (LACC) METHODS AND MATERIALS: Data from medical records of all consecutive patients with histologically proven cervical cancer (FIGO 2018 stage IB-IVA) treated by HDR-BT after CCRT at our institution between 2016 and 2021 were reviewed.

Results: Two hundred and 8 patients with LACC FIGO 2018 stages (IB 20.7%; II 26.

View Article and Find Full Text PDF

: To analyze the results of interstitial (IRT) high-dose-rate (HDR) brachytherapy (BT) in the primary treatment of patients with unresectable superior sulcus tumors (SST) combined with external beam radiotherapy (EBRT). : Between 2013 and 2023, seven patients with unresectable SST were treated with combined BT and EBRT with or without concomitant chemotherapy. The patients' median age was 64 years (range, 49-79 years) and median tumor volume was 146.

View Article and Find Full Text PDF

Technical Aspects of a National Service for Paediatric Pelvic Brachytherapy.

Clin Oncol (R Coll Radiol)

December 2024

Department of Oncology, University College London Hospitals NHS Foundation Trust, 250 Euston Road, London, NW1 2PG, UK. Electronic address:

Aims: Brachytherapy is advantageous for localised rhabdomyosarcomas in children compared with external beam radiotherapy, sparing close organs at risk with highly conformal dosimetry. A methodology for planning and delivering fractionated high-dose-rate paediatric pelvic brachytherapy is detailed, and the dosimetric parameters are presented. This provides a practical template for radiotherapy departments with a similar patient cohort to implement this treatment technique.

View Article and Find Full Text PDF

Application value of personalized 3D printing vaginal model for the Image-guided adaptive brachytherapy of cervical cancer.

J Gynecol Oncol

November 2024

The 3th Ward of Radiotherapy Department, Guangzhou Institute of Cancer Research, The Affiliated Cancer Hospital, Guangzhou Medical University, Guangzhou, China.

Objective: To explore the application value of using 3-dimensional (3D) printing (3DP) technology to create individualized vaginal molds for brachytherapy (BT) in high-dose-rate 3D cervical cancer through reverse engineering of needle placement.

Methods: Prospectively, 11 patients with cervical cancer were treated with 3DP-intracavitary/interstitial (IC/IS) BT using 3DP to create individualized vaginal molds. All patients were performed BT after completion of external beam radiotherapy (EBRT).

View Article and Find Full Text PDF

Purpose: To present an innovative deformable applicator that used Freiburg flap as vaginal applicator with or without free-hand interstitial needles in three-dimensional (3D) high-dose-rate (HDR) brachytherapy for vaginal stump recurrence of cervical cancer.

Material And Methods: Between September 2017 and January 2020, all patients with vaginal stump recurrence after radical hysterectomy of cervical cancer treated with vaginal stump brachytherapy using Freiburg flap as vaginal applicator with or without free-hand interstitial needles were retrospective analyzed. Characteristics related to patients and treatment modality as well as preliminary outcomes and side effects were investigated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!