Objectives: To increase the safety of aortic valve replacement, we developed the 'Caput medusae' method, where the prosthesis is prefixed with circumferential tourniquets prior to knot tying. We assumed that an even distribution of forces may help reduce tissue damage. To confirm this theoretically, we compared forces between knots and tourniquets.

Methods: The experimental set-up included a device with movable acrylic plates, a mounted valve and a set of sutures. Traction forces were measured with a luggage scale. Two different tourniquets were compared individually and as bundles of 15. Force-path curves were generated. Knotting and tourniquet forces of 18 staff surgeons were then compared. Both modalities were measured 10 times on 2 days, resulting in 40 observations per surgeon, or 360 observations per modality.

Results: Polyvinyl chloride tourniquets were stiffer than silicone, expressed by a 1.5- to 1.7-fold higher regression-line slope. Fifteen simultaneous tubes produced force increments 7.9-8.9 times higher than their single counterparts. Overall knotting force was 13.64 ± 5.76 vs tourniquet 1.08 ± 0.48 N. Male surgeons' knotting forces were higher compared to female staff (14.76 ± 6.01 vs 10.73 ± 3.74 N; P < 0.001) while tourniquet forces did not differ (1.09 ± 0.47 vs 1.05 ± 0.49 N; P = 0.459). Dedicated valve surgeons (n = 10) tightened the tourniquets more strongly than inexperienced surgeons (1.20 ± 0.52 vs 0.94 ± 0.37 N; P < 0.001); knotting was similar. Multivariable analysis confirmed only valve experience as a predictor of tourniquet strength (experienced surgeons exerted higher force).

Conclusions: Tourniquets exert less force on the tissue than knots. When distributed over the circumference, they can reduce local tension and avoid potential paravalvular leakage. Complete or partial use of tourniquets may thus be an additional option to enhance surgical safety.

Download full-text PDF

Source
http://dx.doi.org/10.1093/icvts/ivaa135DOI Listing

Publication Analysis

Top Keywords

prior knot
8
knot tying
8
aortic valve
8
valve replacement
8
forces
6
tourniquet fixing
4
fixing prior
4
tying reduces
4
reduces forces
4
forces aortic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!