Objective: The purpose of this study is to determine the feasibility of magnetic resonance imaging (MRI) without general anesthesia (GA) for infants being evaluated for sensorineural hearing loss (SNHL) using the bundle and scan technique.

Study Design: Retrospective study.

Setting: Pediatric tertiary care hospital.

Patients: All infants who underwent MRI using the bundle and scan technique as part of the diagnostic workup for unilateral or bilateral SNHL between June 2016 to April 2019 were included.

Main Outcome Measure: The primary outcome was the proportion of clinically useful images produced.

Results: We reviewed 21 bundle and scan MRI examinations in infants being evaluated for SNHL. Patients had a median age of 10 (range: 6-25) weeks at the time of MRI. Motion artifact was noted in 38% (8/21) of cases. Eighty-six percent (18/21) of the magnetic resonance images produced using the bundle and scan technique were of diagnostic quality and/or sufficient for surgical planning for cochlear implantation. Repeat imaging with GA was required for three cases (14%) as the initial images were not clinically useful. All patients requiring GA had unilateral SNHL. All patients with bilateral SNHL successfully underwent MRI without GA using the bundle and scan technique.

Conclusion: The results of our study demonstrate that it is feasible to perform MRI using the bundle and scan technique in the majority of young infants being evaluated for SNHL. This has the potential to help determine cochlear implant candidacy earlier, reduce exposure to GA, and reduce healthcare costs.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MAO.0000000000002838DOI Listing

Publication Analysis

Top Keywords

bundle scan
24
magnetic resonance
12
infants evaluated
12
mri bundle
12
scan technique
12
feasibility magnetic
8
resonance imaging
8
general anesthesia
8
sensorineural hearing
8
hearing loss
8

Similar Publications

Purpose: To investigate the anatomical features of the femoral tunnel in anatomical and isometric single-bundle ACL reconstruction.

Method: Thirty-two 3-dimensional knee models were reconstructed based on CT scan (average age: 26.5 ± 6.

View Article and Find Full Text PDF

Case 335.

Radiology

November 2024

From the Department of Radiology, Hôpital de Braine l'Alleud, Rue Wayez 35, 1420 Braine-l'Alleud, Belgium.

An 84-year-old female patient presented for routine CT angiography (CTA) of the arteries of the neck following right carotid endarterectomy for 75% stenosis, which had been performed without incident 2 months prior. The patient had also been diagnosed with 72% stenosis of the left carotid artery, although it was asymptomatic and thus endarterectomy was not required. The medical history included arterial hypertension and an incomplete left bundle branch block.

View Article and Find Full Text PDF

Background/aims: To identify whether an intact retinal nerve fibre layer (RNFL) thickness profile could determine the location of the earliest RNFL defect in glaucoma.

Methods: Retrospective longitudinal cohort study of patients with initial unilateral glaucoma who eventually developed new glaucoma in the fellow eye. Guided progression analysis (GPA) of serial optical coherence tomography (OCT) examinations was used to identify the angular locations of the earliest RNFL defect, peak and temporal edge of the baseline RNFL profile and major vessels based on the peripapillary OCT scan circle.

View Article and Find Full Text PDF

Optimal angles for independent femoral tunnel drillings to prevent damage to anatomic structures in single-bundle anterior cruciate ligament reconstruction.

J Orthop Surg Res

November 2024

Guangdong Key Lab of Orthopedic Technology and Implant, General Hospital of Southern Theater Command of PLA, The First School of Clinical Medicine, Southern Medical University, Guangzhou, China.

Purpose: To determine the optimal angles for independent femoral tunnel drillings in single-bundle anterior cruciate ligament reconstruction (ACLR) in different races and genders with the aim of preventing damage to lateral femoral anatomic structures (LFAS), posterior cortex and medial femoral condyle.

Methods: This study included 180 volunteers, including 90 Caucasian and 90 matched Chinese. Magnetic resonance imaging (MRI) was used to scan the knees to create three-dimensional bone models, the ACL femoral footprint centre and the LFAS.

View Article and Find Full Text PDF

Hybrid depth electrodes are increasingly being used for epilepsy monitoring and human neurophysiology research. Microwires extending from the tip of the Behnke-Fried (BF) electrode into (sub)cortical areas allow to isolate single neurons and perform microstimulation. Conventional CT or MRI visualize the entire microwire bundle as an artifact extending from the BF electrode tip with low resolution, without proper identification of individual microwires.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!