Precise and tunable time-controlled drug release system using layer-by-layer films as erodible coatings.

Mater Sci Eng C Mater Biol Appl

Key Laboratory of Functional Polymer Materials and State Key Laboratory of Medicinal Chemical Biology, Institute of Polymer Chemistry, College of Chemistry, Nankai University, Tianjin 300071, China; Collaborative Innovation Center of Chemical Science and Engineering (Tianjin), Tianjin 300071, China. Electronic address:

Published: November 2020

Unlike conventional drug carriers, time-controlled release systems do not release drug immediately, but start to release drug after a predetermined lag time. Coating a drug-loaded core with an erodible barrier is a valid way to defer drug release, however, the complicated erosion behavior of the erodible coatings makes it difficult to predict and tune the lag time. Herein we proposed that dynamic layer-by-layer films, using hydrogen-bonded poly(ethylene glycol)/tannic acid (PEG/TA) film as an example, are ideal erodible coatings, because their erosion mechanism is clear and simple, and they disintegrate at constant rate. As a proof, we demonstrated that the release of bovine serum albumin (BSA) from BMS spheres can be deferred by PEG/TA coating. More importantly, the lag time can be simply tuned by the thickness of the coating. By mixing bimodal mesoporous silica (BMS) spheres coated with different thickness PEG/TA films, multiple pulse release was achieved. Similar release patterns were also successfully achieved in vivo.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.msec.2020.111244DOI Listing

Publication Analysis

Top Keywords

erodible coatings
12
lag time
12
release
8
drug release
8
layer-by-layer films
8
release drug
8
bms spheres
8
drug
5
precise tunable
4
tunable time-controlled
4

Similar Publications

Single-injection subunit vaccine for rabies prevention using lentinan as adjuvant.

Int J Biol Macromol

January 2024

State Key Laboratory of Separation Membranes and Membrane Processes, School of Pharmaceutical Sciences, Tiangong University, Tianjin 300387, China. Electronic address:

Current rabies vaccines require 5 doses to provide full protection from the deadly virus, which significantly reduce the compliance of recipients. To minimize the number of immunizations herein single injection vaccines were developed. First a single injection vaccine was designed using rabies virus glycoprotein (G protein) as antigen.

View Article and Find Full Text PDF

Oral delivery of peptides and biological molecules promises significant benefits to patients as an alternative to daily injections, but the development of these formulations is challenging due to their low bioavailability and high pharmacokinetic variability. Our earlier work focused on the discovery of MEDI7219, a stabilized, lipidated, glucagon-like peptide 1 agonist peptide, and the selection of sodium chenodeoxycholate (Na CDC) and propyl gallate (PG) as permeation enhancer combinations. We hereby describe the development of the MEDI7219 tablet formulations and composition optimization via in vivo studies in dogs.

View Article and Find Full Text PDF

Construction of single-injection vaccine using new time-controlled release system.

Biomater Adv

June 2022

Key Laboratory of Functional Polymer Materials and State Key Laboratory of Medicinal Chemical Biology, Institute of Polymer Chemistry, College of Chemistry, Nankai University, Tianjin 300071, China; School of Chemistry, Tiangong University, Tianjin 300387, China. Electronic address:

Single-injection vaccines may overcome issues, such as high cost and poor patient compliance, of the multi-bolus regimes dominantly used in vaccination. However no such vaccine has been commercialized because time-controlled release, an unconventional release kinetics, is difficult to achieve. Here a new time-controlled release system using dynamic layer-by-layer (LBL) film as erodible coating was used to design single-injection vaccine.

View Article and Find Full Text PDF

Poly(ethyl ethylene phosphonate)-based methacrylic copolymers containing polysiloxane methacrylate (SiMA) co-units are proposed as surface-active additives as alternative solutions to the more investigated polyzwitterionic and polyethylene glycol counterparts for the fabrication of novel PDMS-based coatings for marine antifouling applications. In particular, the same hydrophobic SiMA macromonomer was copolymerized with a methacrylate carrying a poly(ethyl ethylene phosphonate) (PEtEPMA), a phosphorylcholine (MPC), and a poly(ethylene glycol) (PEGMA) side chain to obtain non-water soluble copolymers with similar mole content of the different hydrophilic units. The hydrolysis of poly(ethyl ethylene phosphonate)-based polymers was also studied in conditions similar to those of the marine environment to investigate their potential as erodible films.

View Article and Find Full Text PDF
Article Synopsis
  • In ST-segment-elevation myocardial infarction (STEMI), complete revascularization through angiography is more effective than treating only the culprit lesion, highlighting the importance of assessing nonculprit lesions.
  • This study used quantitative flow ratio (QFR), a non-invasive method without vasodilators, to analyze the significance of untreated nontarget vessels in patients from the COMFORTABLE AMI trial, focusing on outcomes like cardiac death and myocardial infarction over 5 years.
  • Results showed that patients with a QFR ≤0.80 had a significantly higher rate of adverse outcomes compared to those with QFR >0.80, suggesting that QFR is a valuable independent predictor in managing STEMI cases.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!