A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A low-cost LIBS detection system combined with chemometrics for rapid identification of plastic waste. | LitMetric

A low-cost LIBS detection system combined with chemometrics for rapid identification of plastic waste.

Waste Manag

Advanced Centre of Research in High Energy Materials, University of Hyderabad, Prof C R Rao Road, Central University Campus PO, Gachibowli, Hyderabad, Telangana 500046, India. Electronic address:

Published: November 2020

We present, rapid and efficient identification of ten different types of post-consumer plastics obtained from a local recycling unit by deploying a low cost, compact CCD spectrometer in laser-induced breakdown spectroscopy (LIBS) technique. For this investigation, spectral emissions were collected by an Echelle spectrograph equipped with an intensified charge-coupled device (ES-ICCD) as well as a non-gated Czerny Turner CCD spectrometer (NCT-CCD). The performance is evaluated by interrogating the samples in a single-shot as well as accumulation mode (ten consecutive laser shots). The results from principal component analysis (PCA) have shown excellent discrimination. Further, the artificial neural network (ANN) analysis has demonstrated that individual identification accuracies/rates up to ~99 % can be achieved. The data acquired with ES-ICCD in the accumulation of ten shots have shown average identification accuracies ~97 %. Nevertheless, similar performance is achieved with the NCT-CCD spectrometer even in a single shot acquisition which reduces the overall analysis time by a factor of ~15 times compared to the ES-ICCD. Furthermore, the detector/collection system size, weight, and cost also can be reduced by ~10 times by employing a NCT-CCD spectrometer. The results have the potential in realizing a compact and low-cost LIBS system for the rapid identification of plastics with higher accuracies for the real-time application.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.wasman.2020.07.046DOI Listing

Publication Analysis

Top Keywords

low-cost libs
8
rapid identification
8
ccd spectrometer
8
nct-ccd spectrometer
8
identification
5
libs detection
4
detection system
4
system combined
4
combined chemometrics
4
chemometrics rapid
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!