On page 5, in the second paragraph, the authors inadvertently included inaccurate information for the description of the analytical method.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1208/s12248-020-00479-4 | DOI Listing |
Phys Rev Lett
December 2024
University of Science and Technology of China, CAS Key Laboratory of Quantum Information, Hefei 230026, People's Republic of China.
The quantum circuit model is the most widely used theoretical model for quantum computing. Therefore, determining whether two quantum circuits whose internal structures cannot be seen have the same functionality will be a fundamental problem in future quantum industries, which however turns out to be QMA-hard. Here, based on a photonic system we experimentally implement the equivalence checking of two unknown quantum circuits with real unitary matrix representations, where quantum nonlocality plays a key role and allows us to measure an "average-case" distance between the two quantum circuits very efficiently.
View Article and Find Full Text PDFJ Chem Theory Comput
January 2025
Institute for Computational Physics, University of Stuttgart, Allmandring 3, Stuttgart 70569, Germany.
The constant-pH Monte Carlo method is a popular algorithm to study acid-base equilibria in coarse-grained simulations of charge regulating soft matter systems including weak polyelectrolytes and proteins. However, the method suffers from systematic errors in simulations with explicit ions, which lead to a symmetry-breaking between chemically equivalent implementations of the acid-base equilibrium. Here, we show that this artifact of the algorithm can be corrected a-posteriori by simply shifting the pH-scale.
View Article and Find Full Text PDFJ Comput Assist Tomogr
January 2025
Department of Radiology, College of Medicine, University of Florida, Gainesville, FL.
Purpose: This study evaluated beam quality and radiation dosimetry of a CT scanner equipped with a novel detector and filtration technology called PureVision Optics (PVO). PVO features miniaturized electronics, a detector cut with microblade technology, and increased filtration in order to increase x-ray detection and reduce image noise.
Methods: We assessed the performance of two similar 320-detector CT scanners: one equipped with PVO and one without.
Arch Pediatr
January 2025
Robert Debré University Hospital, Assistance Publique des Hôpitaux de Paris (AP-HP), France.
Introduction: The primary objective of this study is to describe the refractive needs of vulnerable children according to their social security status. The secondary objective of this study is to describe the types of ametropia in this population of children with limited access to ocular health care.
Methods: Children with limited access to ocular health care were recruited.
H*10 neutron dosimetry (unlike gamma dosimetry), requires consideration of neutron energy spectra due to the 20× variation of the weight factor over the thermal-to-fast energy range, as well as the neutron radiation field dose rates ranging from cosmic, ~.01 μSv h-1 levels to commonly encountered ~10-200 μSv h-1 in nuclear laboratories/processing plants, and upwards of 104 Sv h-1 in nuclear reactor environments. This paper discusses the outcome of the comparison of spectrum-weighted neutron dosimetry covering thermal-to-fast energy using the novel H*-TMFD spectroscopy-enabled sensor system in comparison with measurements using state-of-the-art neutron dosimetry systems at SRNS-Rotating Spectrometer (ROSPEC), and non-spectroscopic Eberline ASP2E ("Eberline") and Ludlum 42-49B ("Ludlum") survey instrumentation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!