The addition of Fe to TiO is one of the effective methods to inhibit the recombination of photogenerated electrons and holes and thus improve the photocatalytic activity of TiO. The effect of PVDF-PVP-TiO-FeCl (PPTFe) membrane filtration-photocatalytic system on the removal of trace concentration of sulfadiazine (SD) in water was evaluated. A two-factor four-level experiment was established to optimize 16 self-made modified membranes. The optimal membrane was then characterized in seven tests (SEM, EDS, membrane pure water flux, contact angle, porosity, mean pore size, ATR-FTIR), resulting in the optimal ratio (PPTFe membrane with 1.2 wt%TiO and 0.8 wt%FeCl). Compared with the original membrane, the pore number, pore size, permeability, and hydrophilicity of the PPTFe membrane were all enhanced. The removal efficiency (92.63%) of SD by PPTFe membrane filtration-photocatalysis system was investigated. The reaction rate (0.0214 min) of the removal SD of the system was determined according to the pseudo-first-order kinetic model. The removal performance of membrane type, pH, and water quality parameters (Cl, SO, NO, HA) on PPTFe membrane filtration-photocatalytic system were also made a deep inquiry. The results reflected that acidic conditions (pH = 3) were beneficial to SD removal, the presence of Cl, SO, and HA could inhibit SD removal, while the existence of NO was unaffected. Furthermore, the removal rate of SD in the actual water body was displayed well in this system. Finally, the possible photocatalytic degradation mechanism was proposed.Graphical abstract.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11356-020-10426-7 | DOI Listing |
Environ Sci Pollut Res Int
December 2020
Shandong (Jinan) Water & Waste Water Monitoring Center, No. 5111, Aotizhong Road, Jinan, 250101, People's Republic of China.
The addition of Fe to TiO is one of the effective methods to inhibit the recombination of photogenerated electrons and holes and thus improve the photocatalytic activity of TiO. The effect of PVDF-PVP-TiO-FeCl (PPTFe) membrane filtration-photocatalytic system on the removal of trace concentration of sulfadiazine (SD) in water was evaluated. A two-factor four-level experiment was established to optimize 16 self-made modified membranes.
View Article and Find Full Text PDFEnviron Sci Technol
March 2004
Department of Environmental Science, Faculty of Science, Kumamoto University, 2-39-1 Kurokami, Kumamoto 860-8555, Japan.
We describe a membrane-based collection/analysis system that differentially monitors H2S and CH3SH, and to which a conductometric SO2 analyzer using the same collector was coupled. A diffusion scrubber (DS) comprised of a Nafion tube collects H2S selectively while a porous polytetrafluoroethylene (pPTFE) DS collects both H2S and CH3SH. Both gases are measured via their ability to react with fluorescein mercuric acetate (FMA) which results in decreased fluorescence.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!