A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simultaneous Determination of Urine Methotrexate, 7-Hydroxy Methotrexate, Deoxyaminopteroic Acid, and 7-Hydroxy Deoxyaminopteroic Acid by UHPLC-MS/MS in Patients Receiving High-dose Methotrexate Therapy. | LitMetric

Nephrotoxicity, the most important toxicity in high-dose methotrexate (MTX) therapy, is partly caused by the formation of crystal deposits in the kidney due to poor water solubility of MTX and its metabolites 7-hydroxy methotrexate (7-OH MTX), deoxyaminopteroic acid (DAMPA) and 7-hydroxy deoxyaminopteroic acid (7-OH DAMPA). Plasma MTX level-guided urine alkalinization, leucovorin rescue and glucarpidase detoxification are common strategies to overcome MTX-related nephrotoxicity. However, overestimation is a problem for MTX analysis by immunoassays due to the cross-reactivity of MTX metabolites (7-OH MTX and DAMPA). An UHPLC-MS/MS method for the simultaneous determination of MTX, 7-OH MTX, DAMPA and 7-OH DAMPA in human urine was developed, validated and applied in clinical practice. Samples were treated by one-step protein precipitation and analyzed within 3 min. The calibration range was 0.02 to 4 μmol/L for MTX and DAMPA, and 0.1 to 20 μmol/L for 7-OH MTX and 7-OH DAMPA. For all analytes, the intra-day and inter-day bias and imprecision were -8.0 to 7.6 and <9.0%, the internal standard normalized recovery and matrix factor were 92.34 to 109.49 and <20.68%. The plasma MTX and 7-OH MTX levels increased with the urine drug levels, age, serum creatinine and alanine transaminase, but urine could not replace blood for MTX monitoring due to their poor correlation (R, 0.16 to 0.51). Dose-normalized urine and plasma MTX and 7-OH MTX levels were similar between different patient groups (urine pH <7 or ≥7). Due to the large inter-individual variance of the analytes levels in both plasma and urine, these findings should be treated with caution.

Download full-text PDF

Source
http://dx.doi.org/10.2116/analsci.19P481DOI Listing

Publication Analysis

Top Keywords

deoxyaminopteroic acid
16
7-oh mtx
16
7-oh dampa
12
mtx dampa
12
mtx
11
simultaneous determination
8
7-hydroxy methotrexate
8
7-hydroxy deoxyaminopteroic
8
high-dose methotrexate
8
mtx metabolites
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!