Yttrium-90 Radioembolization in the Office-Based Lab.

J Vasc Interv Radiol

Department of Radiology, Division of Vascular & Interventional Radiology, NYU Langone Health, 660 First Ave, Suite 300, New York, NY 10016.

Published: September 2020

Purpose: To evaluate the feasibility and benefits of performing yttrium-90 radioembolization in an office-based lab (OBL) compared to a hospital setting.

Materials And Methods: A radioembolization program was established in March 2019 in an OBL that is managed by the radiology department of a tertiary care center. Mapping and treatment angiograms performed in the OBL from March 2019 through January 2020 were compared to mapping and treatment angiograms performed in the hospital during the same time period.

Results: One hundred seventy-six mapping and treatment angiograms were evaluated. There was no difference in the proportion of mapping versus treatment angiograms performed at each site, the proportion of lobar versus selective dose vial administrations, or the mean number of dose vials administered per treatment procedure. Procedure start delays were longer in the hospital than in the OBL (28.6 minutes vs 0.8 minutes; P < .0001), particularly for procedures that were not scheduled as the first case of the day (hospital later case delay, 38.8 minutes vs OBL later case delay, 0.5 minutes; P < .0001). Procedures performed in the hospital took longer on average than procedures performed in the OBL (2 hours, 1.8 minutes vs 1 hour, 44.4 minutes; P = .0004), particularly for procedures that were not scheduled as the first case of the day (hospital later case duration, 2 hours, 7.4 minutes vs OBL later case duration, 1 hour, 43 minutes; P = .0006).

Conclusions: Establishing a radioembolization program within an OBL is feasible and might provide more efficient procedure scheduling than the hospital setting.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvir.2020.05.002DOI Listing

Publication Analysis

Top Keywords

treatment angiograms
16
mapping treatment
12
angiograms performed
12
yttrium-90 radioembolization
8
radioembolization office-based
8
office-based lab
8
obl
8
radioembolization program
8
march 2019
8
performed obl
8

Similar Publications

Prognostic Value of Myocardial CT-ECV in Severe Aortic Stenosis Requiring Aortic Valve Replacement: A Systematic Review and Meta-analysis.

Eur Heart J Cardiovasc Imaging

January 2025

Department of Perioperative Cardiology and Cardiovascular Imaging, Centro Cardiologico Monzino IRCCS, Milan, Italy.

Aim: Computed tomography (CT)-derived extracellular volume fraction (ECV) is a non-invasive method to quantify myocardial fibrosis. Evaluating CT-ECV during aortic valve replacement (AVR) planning CT in severe aortic stenosis (AS) may aid prognostic stratification. This meta-analysis evaluated the prognostic significance of CT-ECV in severe AS necessitating AVR.

View Article and Find Full Text PDF

Purpose: We describe an atypical presentation of an 11-year-old female with enhanced S-cone syndrome (ESCS).

Methods: Case report. The patient underwent a thorough ophthalmic examination and investigations such as colour fundus photography, optical coherence tomography, fundus autofluorescence, fluorescein and indocyanine angiography, an electroretinogram and genetic testing.

View Article and Find Full Text PDF

Purpose: We investigated changes in macular topography and their association with visual acuity and metamorphopsia in the idiopathic epiretinal membrane (iERM).

Methods: Twenty-four eyes that underwent vitrectomy and ERM removal with internal limiting membrane peeling were included in this study. Best-corrected visual acuity (BCVA) and horizontal/vertical metamorphopsia scores (h and vM-scores in the M-chart) were assessed.

View Article and Find Full Text PDF

Background: Hepatic artery infusion pump (HAIP) chemotherapy is a locoregional treatment for intrahepatic malignancies. HAIPs are surgically implanted, and the catheter tip is typically inserted into a ligated gastroduodenal artery stump. Potential complications at the catheter insertion site include dehiscence, pseudoaneurysm or extravasation, and adjacent hepatic arterial stenosis and thrombosis.

View Article and Find Full Text PDF

Purpose: To evaluate changes in the retinal microvasculature using widefield swept-source optical coherence tomography angiography (SS-OCTA) following three anti-vascular endothelial growth factor (anti-VEGF) loading injections for diabetic macular edema (DME).

Methods: Thirty-four treatment-naïve patients with DME received an initial three loading injections, followed by injections on an as-needed basis. Macular ischemia was evaluated based on the foveal avascular zone (FAZ) area, perfusion density, and vessel density on a 3 × 3-mm SS-OCTA image.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!