Objective:  The aim of this study was to determine the indications for, and complications of, plate removal surgery in horses that underwent internal fixation of limb fractures.

Study Design:  Medical records of horses presented to our hospital between 1990 and 2015 for the removal of plates after treatment of limb fractures were reviewed. Data collected at the time of initial presentation, including signalment, history, fracture features and treatment and information about the indications, timing and complications of implant removal were reviewed.

Results:  The most common bones involved were the ulna ( = 19) and third metacarpal and metatarsal bones ( = 14). A total of 63 plates were removed from 48 horses during 53 separate surgeries, and the complication rate was 6/48; six horses had complications related to implant removal, which included persistent infection ( = 1) and refracture ( = 5). Complications related to implant removal were associated with comminuted fractures ( = 0.002), age > 3 years ( = 0.016) and the presence of surgical site infection ( = 0.001).

Conclusion:  Plate removal after fracture healing is necessary in patients with implant-associated clinical signs. There is a strong relationship between the complication rate and the degree of comminution of the original fracture, increasing age and the presence of surgical site infection. The surgeon must be aware of these risk factors when planning plate removal.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0040-1714411DOI Listing

Publication Analysis

Top Keywords

plate removal
12
complications implant
12
implant removal
12
internal fixation
8
fixation limb
8
limb fractures
8
indications complications
8
complication rate
8
presence surgical
8
surgical site
8

Similar Publications

First metatarsophalangeal joint (MTPJ) fusion an effective surgical intervention for conditions such as hallux valgus and hallux rigidus. This systematic review and meta-analysis aims to compare safety and efficacy of crossed screws versus plating supplemented with an interfragmentary screw. A literature search of the Scopus, Embase, Web of Science, and MEDLINE databases was performed to identify all studies directly comparing the two techniques.

View Article and Find Full Text PDF

Introduction: External fixators are utilized to temporarily stabilize bicondylar tibial plateau fractures. They can be prepped during definitive surgery to help maintain fracture length and alignment. However, there is a potential for increased infection by leaving the external fixator on during the surgery.

View Article and Find Full Text PDF

Steam Generator Maintenance Robot Design and Obstacle Avoidance Path Planning.

Sensors (Basel)

January 2025

College of Resource Environmental and Safety Engineering, University of South China, Hengyang 421001, China.

To solve the issue of inconvenient and dangerous manual operation during the installation and removal of the main pipe plugging plate in the steam generator in nuclear power plants, a ten-degree-of-freedom plugging robot was designed in the present study that includes a collaborative robotic arm coupled with a servo electric cylinder. By establishing a joint coordinate system for the robot model, a D-H parameter model for the plate plugging robot was established, and the forward and inverse kinematics were solved. The volume level approximate convex decomposition algorithm was used to fit the steam generator model with a convex packet, and an experimental simulation platform was constructed.

View Article and Find Full Text PDF

Medial Open-Wedge High Tibial Osteotomy with Partial Meniscectomy and Without Cyst Excision for Popliteal Cysts: A Case Series.

Biomedicines

January 2025

Department of Orthopaedic Surgery, Hallym Sacred Heart University Hospital, Hallym University, Anyang-si 13496, Republic of Korea.

Popliteal cysts (PCs) are occasionally accompanied by knee osteoarthritis (OA) and varus malalignment. However, whether concomitant arthroscopic excision of PCs with medial open-wedge high tibial osteotomy (MOWHTO) improves the osteoarthritic environment remains unclear. Therefore, this study assessed serial changes in C-size, medial meniscus extrusion (MME), and cartilage status for up to 2 years following an MOWHTO.

View Article and Find Full Text PDF

Background/objectives: Micropulse laser trabeculoplasty (MLT) is gaining attention as a non-invasive treatment option for primary open-angle glaucoma (POAG), offering an alternative to traditional surgeries and medications. This systematic review evaluates the effectiveness, safety, and potential of MLT in glaucoma management.

Methods: This review adhered to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!