A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Continuous positive airway pressure effectively ameliorates arrhythmias in patients with obstructive sleep apnea-hypopnea via counteracting the inflammation. | LitMetric

Introduction: This work is aimed at evaluating the therapeutic effect of continuous positive airway pressure (CPAP) in treatment of patients with obstructive sleep apnea-hypopnea syndrome (OSAHS) combined with arrhythmias as well as clarifying the possible mechanism underpinning such an intervention.

Methods: Through exclusions, a total of 108 OSAHS patients combined with arrhythmias were enrolled from June 2017 to June 2019 with full clinical information in this work. A computerized permuted block design with varying block stratification and size according to age, sex, AHI and type of arrhythmia was used to randomize 108 patients to CPAP versus sham CPAP for a period of 12-week. All were subjected to unchanged pharmacological anti-arrhythmia therapy combined with CPAP. Before and after CPAP treatment, the improvement of various arrhythmias was compared between the CPAP group and the sham-CPAP group. The levels of CRP, IL-6 and TNF-ɑ were measured simultaneously.

Results: During follow-up, the mean (±SD) CPAP pressure used in the CPAP group was 12.3 (±3.1) cm H2O. The use of CPAP and sham CPAP was on average of 5.2 ± 0.56 and 5.1 ± 0.63 h/night, respectively. After 12 weeks of CPAP therapy, the AHI was significantly decreased and the lowest blood oxygen saturation was notably elevated in the CPAP group compared to the sham-CPAP group, P < 0.05. The CPAP therapy, compared with the sham-CPAP group, significantly reduced the incidence of all types of arrhythmia in patients with OSAHS. The level of the c-reactive protein (CRP), interleukin-6 (IL-6), and tumor necrosis factor-α (TNF-α) was significantly lower in the CPAP group than in the sham-CPAP group (P < 0.05). Pearson correlation analysis showed that the reduction in the incidence of total arrhythmias was positively correlated with the decrease of CRP, IL-6 and TNF-ɑ levels, respectively.

Conclusion: Findings from this work suggest that proper use of CPAP significantly benefits to OSAHS patients combined with arrhythmias, possibly via counteracting the inflammation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjoto.2020.102655DOI Listing

Publication Analysis

Top Keywords

cpap
12
cpap group
12
continuous positive
8
positive airway
8
airway pressure
8
patients obstructive
8
obstructive sleep
8
sleep apnea-hypopnea
8
pressure cpap
8
cpap treatment
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!