A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Design of an automatic spectrophotometric system. | LitMetric

AI Article Synopsis

  • A new 3D printed Multi-Syringe Flow Injection Analysis (MSFIA) system was created to measure quinine levels in soft drinks using a CCD detector and LED light source.
  • The system connects to a computer and utilizes an AutoAnalysis program for data collection and analysis, providing more accurate results than traditional manual methods.
  • This innovative approach helps decrease reagent use, minimize environmental impact, and lower measurement costs.

Article Abstract

A Multi-Syringe Flow Injection Analysis (MSFIA) fluorometric system based on a 3D printing device hosting a CCD detector has been designed for the determination of quinine in soft drinks. A LED controlled by an electronic circuit was used as a radiation source. The entire system is connected to two USB outputs of a computer. The AutoAnalysis program has been used for data acquisition and treatment. The results are more accurate and precise than those obtained with a manual method using a conventional spectrofluorometer. This developed system is a viable alternative to reduce the consumption of reagents, the impact on the environment and reduce measurement costs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2020.121163DOI Listing

Publication Analysis

Top Keywords

design automatic
4
automatic spectrophotometric
4
system
4
spectrophotometric system
4
system multi-syringe
4
multi-syringe flow
4
flow injection
4
injection analysis
4
analysis msfia
4
msfia fluorometric
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!