A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Congener-specific determination of hydroxylated polychlorinated biphenyls by polar-embedded reversed-phase liquid chromatography-tandem mass spectrometry. | LitMetric

This paper reports the development of an LC-ESI-MS method for the sensitive determination of hydroxylated polychlorinated biphenyls (OH-PCBs) in human serum samples. Congener-specific separation was achieved by using a polar-embedded stationary phase, previously optimized for the working group, which provided better separation of isobaric compounds than the common octadecylsilane phases. MS fragmentation patterns and energies showed differences among OH-PCB congeners, mainly depending on the position of OH-group and the number of chlorine atoms in the molecule, although the most intense transitions were always those corresponding to the neutral loss of an HCl group from the quasi-molecular ion cluster. The method allowed the determination of OH-PCBs with good linearity (dynamic linear range of four orders of magnitude with R higher than 0.995) and precision (relative standard deviations of absolute areas lower than 10%), and with better sensitivity than other similar methods previously described in the literature. Matrix effect has been evaluated and reduced to less than 10% by the addition of isotopically labeled standards and a 10-fold dilution of the final sample extract. The low iLODs provided by the developed method (from 1.2 to 5.4 fg µL for all the OH-PCBs studied, except 4'-OHCB108, whose iLOD was 61 fg µL) allows dilution without losses of detected peaks. Finally, the applicability of the method has been demonstrated by analyzing human serum samples belonging to an interlaboratory exercise.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2020.461353DOI Listing

Publication Analysis

Top Keywords

determination hydroxylated
8
hydroxylated polychlorinated
8
polychlorinated biphenyls
8
human serum
8
serum samples
8
congener-specific determination
4
biphenyls polar-embedded
4
polar-embedded reversed-phase
4
reversed-phase liquid
4
liquid chromatography-tandem
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!