Biocompatible SPME fibers for direct monitoring of nicotine and its metabolites at ultra trace concentration in rabbit plasma following the application of smoking cessation formulations.

J Chromatogr A

Department of Chemistry and Biochemistry, College of Natural Sciences and Mathematics, The University of Toledo, Toledo, OH 43606, USA.; School of Green Chemistry and Engineering, The University of Toledo, Toledo, OH 43606, USA.; Dr. Nina McClelland Laboratory for Water Chemistry and Environmental Analysis, The University of Toledo, Toledo, OH 43606, USA. Electronic address:

Published: August 2020

The ultra-trace determination of nicotine and its 4 major metabolites (cotinine, nornicotine, norcotinine and anabasine) from rabbit plasma was achieved by a newly developed solid phase microextraction-liquid chromatography-tandem mass spectrometry method. Extraction of the target analytes was performed with hydrophilic/lipophilic balance-polyacrylonitrile SPME fibers. Dual fiber extraction was necessary to guarantee improved recovery at parts-per-trillion levels. Liquid chromatographic analysis was achieved in a 6-min run using a C18 (1.9 µm C18, 50 mm x 2.1 mm) column with a mobile phase flow rate of 0.4 mL/min. Tandem mass spectrometry was used for detection and quantification in positive electrospray ionization (ESI+) mode for all the targeted analytes. Two stable isotope-labeled internal standards were used for signal correction and accurate quantification. The mass spectrometer with laminar flow ion flux transport, guaranteed improved signal stability, minimal contamination of the ion guide and reproducibility into the first quadrupole analyzer. The method was validated in line with the Food and Drug Administration (FDA) guidelines for bioanalytical method validation. The results met the acceptance criteria as proposed by the FDA: accuracy was tested at 0.35, 10 and 75 µg L   and ranged between 98.3-112.2% for nicotine, 94.1-101.9% for cotinine, 94.7-107.0% for nornicotine, 81.1-107.2% for norcotinine and 94.3-115.2% for anabasine, with precision up to 14.2%. Stability tests indicated that all the targeted analytes were stable in the desorption solution for at least 1 week. LOQs ranged from 0.05 to 1 µg L. The method was successfully applied to analyze plasma samples obtained from rabbits following transdermal application of a smoking cessation formulation loaded with solid lipid nanoparticles containing a nicotine-stearic acid conjugate.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2020.461333DOI Listing

Publication Analysis

Top Keywords

spme fibers
8
rabbit plasma
8
application smoking
8
smoking cessation
8
mass spectrometry
8
targeted analytes
8
analytes stable
8
biocompatible spme
4
fibers direct
4
direct monitoring
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!