A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Optimization of the radiosynthesis of [68Ga]Ga-PSMA-11 using a Trasis MiniAiO synthesizer: do we need to heat and purify? | LitMetric

Unlabelled: INTRODUTION:: [Ga]Ga-prostate specific membrane antigen (PSMA)-11 showed a clear gain in sensitivity for lesion detection in the biological recurrence of prostate cancer as compared to the standard [F]fluorocholine radiopharmaceutical. To meet the strong demand for [Ga]Ga-PSMA-11, we aimed to optimize an automated radiolabeling process by evaluating the influence of different key parameters on radiochemical purity and radiochemical yield.

Methods: The radiosynthesis of [Ga]Ga PSMA-11 was performed using a Trasis MiniAio synthesizer and a Ge/Ga GalliaPharm generator supplied by Eckert & Ziegler, Berlin, Germany. Optimized labeling parameters were evaluated by variation of sodium acetate concentrations and temperature of radiolabeling as well as the purification process.

Results: For each condition tested, radiochemical purity was higher than 99% in the final vial without batch failure, indicating a robust and fast radiosynthesis process. Radiosynthesis without the solid phase extraction purification process at room temperature in less than 5 min resulted in a radiolabeling efficiency of over 99% and remained stable at least 4 h without manual processing to limit operator radiation exposure.

Conclusion: The procedure was completely automated and provided a high radiochemical yield. It can be performed several times a day, facilitating the clinical demand of this radiopharmaceutical.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MNM.0000000000001233DOI Listing

Publication Analysis

Top Keywords

trasis miniaio
8
miniaio synthesizer
8
radiochemical purity
8
optimization radiosynthesis
4
radiosynthesis [68ga]ga-psma-11
4
[68ga]ga-psma-11 trasis
4
synthesizer heat
4
heat purify?
4
purify? unlabelled
4
unlabelled introdution
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!