From 1310.6×10^{6} J/ψ and 448.1×10^{6} ψ(3686) events collected with the BESIII experiment, we report the first observation of Σ^{+} and Σ[over ¯]^{-} spin polarization in e^{+}e^{-}→J/ψ[ψ(3686)]→Σ^{+}Σ[over ¯]^{-} decays. The relative phases of the form factors ΔΦ have been measured to be (-15.5±0.7±0.5)° and (21.7±4.0±0.8)° with J/ψ and ψ(3686) data, respectively. The nonzero value of ΔΦ allows for a direct and simultaneous measurement of the decay asymmetry parameters of Σ^{+}→pπ^{0}(α_{0}=-0.998±0.037±0.009) and Σ[over ¯]^{-}→p[over ¯]π^{0}(α[over ¯]_{0}=0.990±0.037±0.011), the latter value being determined for the first time. The average decay asymmetry, (α_{0}-α[over ¯]_{0})/2, is calculated to be -0.994±0.004±0.002. The CP asymmetry A_{CP,Σ}=(α_{0}+α[over ¯]_{0})/(α_{0}-α[over ¯]_{0})=-0.004±0.037±0.010 is extracted for the first time, and is found to be consistent with CP conservation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1103/PhysRevLett.125.052004 | DOI Listing |
Prostate Cancer
April 2020
Department of Electrical Engineering, Eindhoven University of Technology, De Rondom 70, 5612 AP, Eindhoven, Netherlands.
Objective: To compare prostate cancer detection rates (CDRs) and pathology results with targeted prostate biopsy (TB) and systematic prostate biopsy (SB) in biopsy-naive men.
Methods: An in-patient control study of 82 men undergoing SB and subsequent TB in case of positive prostate MRI between 2015 and 2017 in the Jeroen Bosch Hospital, the Netherlands.
Results: Prostate cancer (PCa) was detected in 54.
BMC Urol
April 2019
Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
Background: To overcome the limitations regarding two dimensional (2D) greyscale (GS) transrectal ultrasound (TRUS)-guided biopsy in prostate cancer (PCa) detection and tissue packaging in biopsy processing, there is an ongoing focus on new imaging and pathology techniques. A three-dimensional (3D) model of the prostate with biopsy needle guidance can be generate by the Navigo™ workstation (UC-care, Israel). The SmartBX™ system (UC-care, Israel) provides a prostate biopsy core preembedding method.
View Article and Find Full Text PDFWorld J Urol
June 2018
Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
Purpose: To determine the value of a three-dimensional (3D) greyscale transrectal ultrasound (TRUS)-guided prostate biopsy system and biopsy core pre-embedding method on concordance between Gleason scores of needle biopsies and radical prostatectomy (RP) specimens.
Methods: Retrospective analysis of prostate biopsies and subsequent RP for PCa in the Jeroen Bosch Hospital, the Netherlands, from 2007 to 2016. Two cohorts were analysed: conventional 2D TRUS-guided biopsies and RP (2007-2013, n = 266) versus 3D TRUS-guided biopsies with pre-embedding (2013-2016, n = 129).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!