Test-retest reliability of left and right ventricular systolic function by new and conventional echocardiographic and cardiac magnetic resonance parameters.

Eur Heart J Cardiovasc Imaging

Division of Cardiology, Department of Cardiovascular Diseases, Cliniques Universitaires St. LucPôle de Recherche Cardiovasculaire (CARD), Institut de Recherche Expérimentale et Clinique (IREC), Université Catholique de Louvain (UCLouvain), Av Hippocrate 10/2806, B-1200 Woluwe St. Lambert, Brussels, Belgium.

Published: September 2021

Aims: Reproducible evaluation of left (LV) and right ventricular (RV) function is crucial for clinical decision-making and risk stratification. We evaluated whether speckle-tracking echocardiography (STE) and cardiac magnetic resonance feature-tracking (cMR-FT) global longitudinal (GLS) and circumferential strains allow better test-retest reproducibility of LV and RV systolic function than conventional cMR and echocardiographic parameters.

Methods And Results: Thirty healthy volunteers and 20 chronic heart failure patients underwent cMR and STE twice on separate days to evaluate test-retest coefficient of variation (CV), intraclass correlation coefficient (ICC) and estimated sample sizes for significant changes in LV and RV function. Among LV parameters, cMR-left ventricular ejection fraction (LVEF) had the highest reproducibility (CV = 6.7%, ICC = 0.98), significantly better than cMR-FT-GLS (CV = 15.1%, ICC = 0.84), global circumferential strains (CV = 11.5%, ICC = 0.94) and echocardiographic LVEF (CV = 11.3%, ICC = 0.93). STE-LV-GLS (CV = 8.9%, ICC = 0.94) had significantly better reproducibility than cMR-FT-LV-GLS. Among RV parameters, STE-RV-GLS (CV = 7.3%, ICC = 0.93) had significantly better CV than cMR-right ventricular ejection fraction (RVEF) (CV = 13%, ICC = 0.82). cMR-FT-RV-GLS (CV = 43%, ICC = 0.39) performed poorly with significantly lower reproducibility than all other RV parameters. Owing to their superior interstudy reproducibility, cMR-LVEF (n = 12), cMR-RVEF (n = 41), STE-LV-GLS and STE-RV-GLS (both n = 14) were the parameters allowing the lowest calculated sample sizes to detect 10% change in LV or RV systolic function.

Conclusion: STE-LV-GLS and STE-RV-GLS showed higher test-retest reliability than other echocardiographic measurements of LV and RV function. They also allowed smaller calculated sample sizes, supporting the use of STE-LV and RV-GLS for longitudinal follow-up of LV and RV function.

Download full-text PDF

Source
http://dx.doi.org/10.1093/ehjci/jeaa206DOI Listing

Publication Analysis

Top Keywords

sample sizes
12
test-retest reliability
8
left ventricular
8
systolic function
8
function conventional
8
cardiac magnetic
8
magnetic resonance
8
circumferential strains
8
ventricular ejection
8
ejection fraction
8

Similar Publications

Digital muscle reconstructions have gained attraction in recent years, serving as powerful tools in both educational and research contexts. These reconstructions can be derived from various 2D and 3D data sources, enabling detailed anatomical analyses. In this study, we evaluate the efficacy of surface scans in accurately reconstructing the volumes of the rotator cuff and teres major muscles across a diverse sample of hominoids.

View Article and Find Full Text PDF

This study investigates the enhancement of solar cell efficiency using nanofluid cooling systems, focusing on citrate-stabilized and PVP-stabilized silver nanoparticles. Traditional silicon-based and perovskite solar cells were examined to assess the impact of these nanofluids on efficiency improvement and thermal management. A Central Composite Design (CCD) was employed to vary nanoparticle concentration (0.

View Article and Find Full Text PDF

Background: The detection of a local per- and polyfluoroalkyl substances (PFAS) pollution hotspot in Zwijndrecht (Belgium) necessitated immediate action to address health concerns of the local community. Several human biomonitoring (HBM) studies were initiated, gathering cross-sectional exposure data from more than 10,000 participants. The linkage of these HBM data with primary care health registries might be a useful new tool in environmental health analysis.

View Article and Find Full Text PDF

Economic impact of prolonged tracheal extubation times on operating room time overall and for subgroups of surgeons: a historical cohort study.

BMC Anesthesiol

January 2025

Department of Anesthesiology, Perioperative Medicine and Pain Management, 1611 NW 12, University of Miami, Miami, FL, 33136, USA.

Background: Prolonged tracheal extubation time is defined as an interval ≥ 15 min from the end of surgery to extubation. An earlier study showed that prolonged extubations had a mean 12.4 min longer time from the end of surgery to operating room (OR) exit.

View Article and Find Full Text PDF

Objective: Post-cesarean delivery (CD) acute pain may progress to chronic pain, which may impair maternal bonding and child development. In 2013, we compared the efficacy of versus on-demand oral analgesia for post-caesarean pain in a randomized-controlled-trial. The fixed-time-interval group had received scheduled paracetamol, tramadol, and diclofenac regardless of pain level, and the on-demand group received medication as needed, with oxycodone reserved for unrelieved pain in both groups.

View Article and Find Full Text PDF