The juxta-anastomotic stenosis of an arteriovenous fistula (AVF) is a significant clinical problem in hemodialysis patients with no effective treatment. Previous studies of AV anastomotic angles on hemodynamics and vascular wall injury were based on computational fluid dynamics (CFD) simulations using standardized AVF geometry, not the real-world patient images. The present study is the first CFD study to use angiographic images with patient-specific outcome information, i.e., the exact location of the AVF stenotic lesion. We conducted the CFD analysis utilizing patient-specific AVF geometric models to investigate hemodynamic parameters at different locations of an AVF, and the association between hemodynamic parameters and the anastomotic angle, particularly at the stenotic location. We analyzed 27 patients who used radio-cephalic AVF for hemodialysis and received an angiographic examination for juxta-anastomotic stenosis. The three-dimensional geometrical model of each patient's AVF was built using the angiographic images, in which the shape and the anastomotic angle of the AVF were depicted. CFD simulations of AVF hemodynamics were conducted to obtain blood flow parameters at different locations of an AVF. We found that at the location of the stenotic lesion, the AV angle was significantly correlated with access flow disturbance ( = 0.739; < 0.001) and flow velocity ( = 0.563; = 0.002). Furthermore, the receiver operating characteristic (ROC) curve analysis revealed that the AV angle determines the lesion's flow disturbance with a high area under the curve value of 0.878. The ROC analysis also identified a cut-off value of the AV angle as 46.5°, above or below which the access flow disturbance was significantly different. By applying CFD analysis to real-world patient images, the present study provides evidence that an anastomotic angle wider than 46.5° might lead to disturbed flow generation, demonstrating a reference angle to adopt during the anastomosis surgery.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7390971PMC
http://dx.doi.org/10.3389/fbioe.2020.00846DOI Listing

Publication Analysis

Top Keywords

anastomotic angle
16
flow disturbance
16
avf
10
arteriovenous fistula
8
juxta-anastomotic stenosis
8
cfd simulations
8
real-world patient
8
patient images
8
images study
8
angiographic images
8

Similar Publications

The effective prevention and treatment of anastomotic leakage after intestinal anastomosis for colorectal diseases is still a major clinical challenge. In order to assist intestinal anastomosis healing and avoid anastomotic leakage caused by high tension, low blood supply or infection, we designed a double-layer nanofiber intestinal anastomosis scaffold, which was composed of electrospun PTMC/PHA nanofibers as the main layer, and electrospun PVA/OHA-Gs nanofibers with antibacterial properties as the antibacterial surface layer. This double-layer scaffold has good toughness, its maximum tensile force value could reach 8 N, elongation could reach 400 %, and it has hydrophilic properties, and its contact angle was about 60°.

View Article and Find Full Text PDF

Distal Pancreatectomy with Celiac Axis and Venous Resection with Hepatic Artery and Venous Reconstruction (DP-CARV) for Locally Advanced Pancreatic Adenocarcinoma.

Ann Surg Oncol

December 2024

Hepato-Pancreato-Biliary Surgery and Liver Transplantation, Pôle des Pathologies Hépatiques et Digestives, Hôpital de Hautepierre-Hôpitaux Universitaires de Strasbourg, Université de Strasbourg, Strasbourg, France.

Background: Surgery has recently been introduced into the multimodal management of patients with locally advanced pancreatic adenocarcinomas (LAPCs) thanks to the major pathological response seen with the advent of the multiagent regimen FOLFIRINOX. Distal pancreatectomy with celiac axis resection (DP-CAR) may be complicated by ischemic liver and gastric events. Common hepatic artery reconstruction may prevent the occurrence of ischemic complications and can be an alternative to preoperative embolization of the celiac trunk.

View Article and Find Full Text PDF
Article Synopsis
  • * These disturbances can cause complications such as endothelial dysfunction and vascular stenosis, leading to low patency rates and potential cardiac issues.
  • * The review discusses various techniques and modifications, including surgical methods and graft designs, aimed at correcting hemodynamic problems to improve long-term patient outcomes.
View Article and Find Full Text PDF
Article Synopsis
  • - Para-duodenal hernias account for 53% of internal hernias, mostly occurring on the left side, with rare symptoms in adults and a higher prevalence in males; right para-duodenal hernias are particularly uncommon and often discovered during emergency surgeries.
  • - A 71-year-old male experienced severe abdominal pain, nausea, and vomiting, leading to a CT scan that identified a right para-duodenal hernia, resulting in an emergency surgery where the hernia was confirmed.
  • - Internal hernias, while rare, lead to significant complications like bowel obstruction and ischemia; due to the patient's extensive symptoms at presentation, an exploratory laparotomy was chosen as the surgical approach, ultimately resulting in a full recovery.
View Article and Find Full Text PDF

Purpose: This study investigates the effects of hexagonal microtextured titanium sheets on fibroblast growth and collagen synthesis, crucial factors in anastomotic healing.