A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Intensity Augmentation to Improve Generalizability of Breast Segmentation Across Different MRI Scan Protocols. | LitMetric

Objective: The segmentation of the breast from the chest wall is an important first step in the analysis of breast magnetic resonance images. 3D U-Nets have been shown to obtain high segmentation accuracy and appear to generalize well when trained on one scanner type and tested on another scanner, provided that a very similar MR protocol is used. There has, however, been little work addressing the problem of domain adaptation when image intensities or patient orientation differ markedly between the training set and an unseen test set. In this work we aim to address this domain shift problem.

Method: We propose to apply extensive intensity augmentation in addition to geometric augmentation during training. We explored both style transfer and a novel intensity remapping approach as intensity augmentation strategies. For our experiments, we trained a 3D U-Net on T1-weighted scans. We tested our network on T2-weighted scans from the same dataset as well as on an additional independent test set acquired with a T1-weighted TWIST sequence and a different coil configuration.

Results: By applying intensity augmentation we increased segmentation performance for the T2-weighted scans from a Dice of 0.71 to 0.88. This performance is very close to the baseline performance of training with T2-weighted scans (0.92). On the T1-weighted dataset we obtained a performance increase from 0.77 to 0.85.

Conclusion: Our results show that the proposed intensity augmentation increases segmentation performance across different datasets.

Significance: The proposed method can improve whole breast segmentation of clinical MR scans acquired with different protocols.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TBME.2020.3016602DOI Listing

Publication Analysis

Top Keywords

intensity augmentation
20
t2-weighted scans
12
breast segmentation
8
test set
8
segmentation performance
8
intensity
6
segmentation
6
augmentation
5
scans
5
performance
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!