Aims: OptiVol fluid index was developed as a transthoracic impedance-based indicator of short-term risk for heart failure hospitalization (HFH). OptiVol is calculated as the accumulating difference between daily impedance (measured impedance) and long-term average impedance (reference impedance). Measured impedance alone was thought to have limited prognostic utility; however, measured impedance has the advantage of being simple, direct, and possibly additive to OptiVol fluid index in establishing long-term HFH risk. We tested the hypothesis that directly measured impedance has independent prognostic value in predicting long-term HFH risk and that changes in measured impedance result in a change in predicted long-term HFH risk.
Methods And Results: A retrospective analysis of 1719 patients studied in PARTNERS-HF, FAST, and RAFT studies was performed. Baseline measured impedance was determined using daily values averaged over 1 month, from Month 6 to 7 post implant; change in measured impedance was determined from values averaged over 1 month, from Month 7 to 8 post implant compared with baseline. The predictive value of baseline measured impedance for HFHs was assessed beginning 7 months post implant. The predictive value of a change in measured impedance for a change in HFHs was assessed beginning 8 months post implant. Baseline measured impedance successfully predicted HFHs. For example, 3 year HFH rate for low baseline impedance < 70 Ω was 23%; for high baseline impedance ≥ 70 Ω was 15% (P < 0.001). Changes in measured impedance resulted in changes in predicted HFHs. For example, when a baseline impedance of ≥70 fell during follow-up to <70 Ω, the subsequent HFHs were 15% compared with 4% in patients with measured impedance that remained >70 Ω (P = 0.004). In addition, when baseline measured impedance fell during follow-up by >1%, 2%, or 3%, subsequent HFHs increased to 13%, 17%, or 18%, respectively. Finally, the prognostic value of measured impedance was additive to the prognostic value of the OptiVol fluid index.
Conclusions: Direct measurements of intrathoracic impedance using an implanted device can be used to stratify patients at varying risk of long-term HFH. These direct measurements of impedance have practical clinical appeal because they are simple, continuous, and ambulatory.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7524260 | PMC |
http://dx.doi.org/10.1002/ehf2.12930 | DOI Listing |
Endocrine
January 2025
Department of Endocrinology and Metabolic Diseases, Manisa Celal Bayar University Hospital, Manisa, Turkey.
Purpose: Our study evaluated skeletal muscle mass, function and quality among mild autonomous cortisol secretion (MACS) patients and non-functioning adrenal incidentaloma (NFAI) patients in comparison with the control group without adrenal mass.
Methods: 63 NFAI (49 female, 14 male) and 31 MACS (24 female, 7 male) patients were included in the study. As the control group, 44 patients (31 women, 13 men) who were known to have no radiological adrenal pathology on computed tomography or magnetic resonance imaging performed for other reasons were selected.
J Neuroeng Rehabil
January 2025
Department of BioMechanical Engineering, Delft University of Technology, Mekelweg 2, Delft, 2628 CD, South-Holland, The Netherlands.
Duchenne Muscular Dystrophy (DMD) progressively leads to loss of limb function due to muscle weakness. The incurable nature of the disease shifts the focus to improving quality of life, including assistive supports to improve arm function. Over time, the passive joint impedance (Jimp) of people with DMD increases.
View Article and Find Full Text PDFAnal Chem
January 2025
School of Mechanical and Robotics Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Republic of Korea.
Electrochemical impedance spectroscopy has great potential for laboratory blood tests. The overall aim of this study is to develop a microfluidic sensor for determining the physical properties and hematological parameters of blood based on its dielectric spectra. Impedance was measured in flowing blood to prevent aggregation and sedimentation at frequencies between 40 Hz and 110 MHz.
View Article and Find Full Text PDFNutrients
January 2025
Department of Sports Medicine and Sports Nutrition, Ruhr University Bochum, 44801 Bochum, Germany.
Background/objectives: Low energy availability (LEA) can cause impaired reproductive function, bone health issues, and suppressed immune function, and may result in decreased performance and overall health status. The purpose of this study was to investigate adaptions of body composition, blood status, resting metabolic rate, and endurance performance to gain more comprehensive insights into the symptoms of LEA and the adaptive effects in the athlete population (active women (n = 11) and men (n = 11)).
Methods: Three treatments were defined as 45 (EA45, control), 30 (EA30), and 10 (EA10) kcal/kg FFM/day and randomly assigned.
Polymers (Basel)
January 2025
Research School of Chemical and Biomedical Technologies, Tomsk Polytechnic University, Lenin Ave. 30, 634050 Tomsk, Russia.
Laser reduction of graphene oxide (GO) is a promising approach for achieving flexible, robust, and electrically conductive graphene/polymer composites. Resulting composite materials show significant technological potential for energy storage, sensing, and bioelectronics. However, in the case of insulating polymers, the properties of electrodes show severely limited performance.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!