In this work, we present the optical birefringence properties of the optical fiber cladding that exists as an evanescent field where the refractive index (RI) of the analysis solution is applied for optical sensor aspiration. To enhance the performance of the sensor, we have investigated the sensor with different thicknesses of TiO coating and bimetallic (Ag-Al) film alloy combinations by thermal evaporation coating. We described a special balanced homodyne detection method for the intensity difference change between the p- and s-polarization lights in the surface plasmon resonance sensing systems, which is strongly determined by the RI of the test medium. The plasmonic optical fiber can measure a very small change of the RI of a glycerol solution, which is a resolution of 4.37 × 10 RI unit (RIU). This method has great advantages of a small-sized optical setup, high stability, high selectivity, easy chemical modification, and low cost. Furthermore, because of the experiment results, we observe that our approach can also eliminate the surrounding noise in the Mach-Zehnder interferometer, which shows the feasibility of this proposed technique. We demonstrate the fluorescence enhancement in detecting the C-reactive protein antibody conjugated with fluorescein isothiocyanate by means of near-field coupling between surface plasmons and fluorophores at spectral channels of emission. This technique can also be extended for application in a biomedical assay and in biochemical science, including molecular diagnostics relying on multichannels that require a small volume of the analyte at each channel which would suffer from the weakness of fluorescence if it were not for the enhancement technology.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.langmuir.0c01793DOI Listing

Publication Analysis

Top Keywords

optical fiber
12
surface plasmon
8
fiber cladding
8
detection method
8
biomedical assay
8
fluorescence enhancement
8
optical
6
bimetallic thin-film
4
thin-film combination
4
combination surface
4

Similar Publications

Selective activation of mesoscale functional circuits via multichannel infrared stimulation of cortical columns in ultra-high-field 7T MRI.

Cell Rep Methods

January 2025

Department of Neurosurgery of the Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310029, China; Interdisciplinary Institute of Neuroscience and Technology, School of Medicine, Zhejiang University, Hangzhou 310029, China; National Key Laboratory of Brain and Computer Intelligence, Zhejiang University, Hangzhou 310058, China; Key Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou 310027, China; MOE Frontier Science Center for Brain Science and Brain-Machine Integration, School of Brain Science and Brain Medicine, Zhejiang University, Hangzhou 310012, China. Electronic address:

To restore vision in the blind, advances in visual cortical prosthetics (VCPs) have offered high-channel-count electrical interfaces. Here, we design a 100-fiber optical bundle interface apposed to known feature-specific (color, shape, motion, and depth) functional columns that populate the visual cortex in humans, primates, and cats. Based on a non-viral optical stimulation method (INS, infrared neural stimulation; 1,875 nm), it can deliver dynamic patterns of stimulation, is non-penetrating and non-damaging to tissue, and is movable and removable.

View Article and Find Full Text PDF

The relationship between optical coherence tomography and magnetic resonance imaging measurements in people with multiple sclerosis: A systematic review and meta-analysis.

J Neurol Sci

January 2025

Department of Neurology, Jacobs Comprehensive MS Treatment and Research Center, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, NY, USA.

Background: Several studies show that optical coherence tomography (OCT) metrics e with cognition, disability, and brain structure in people with multiple sclerosis (PwMS). This review the correlation between OCT parameters and magnetic resonance imaging (MRI) measurements in PwMS.

Methods: A comprehensive search of PubMed/MEDLINE, Embase, Scopus, and Web of Science was performed, including studies published in English up to November 29, 2024 to identify studies reporting quantitative data on the correlation between baseline OCT parameters and MRI measurements in PwMS.

View Article and Find Full Text PDF

Prcis: The discriminant function of glaucoma, obtained by the Laguna ONhE colorimetric program, significantly correlates with the BMO-MRW. Furthermore, the diagnostic capacity was inferior to other structural tests in POAG patients.

Purpose: To evaluate the diagnostic capability for glaucoma and the correlation between peripapillary and macular parameters using spectral domain optical coherence tomography (SD-OCT) and optic nerve head hemoglobin (OHN Hb) levels assessed by the Laguna ONhE® software using colorimetric analysis.

View Article and Find Full Text PDF

A three-dimensional (3D) waveguide model is applied in extreme ultraviolet (EUV) lithography simulations. The 3D waveguide model is equivalent to rigorous coupled-wave analysis, but fewer field components are used to solve Maxwell's equations. The 3D waveguide model uses two components of vector potential, and , corresponding to the two polarizations.

View Article and Find Full Text PDF

On the heels of the continuous development of optical fiber sensing technology, optical fiber sensors based on surface plasmon resonance (SPR) have attracted widespread attention. Herein, an SPR sensor based on the six nested anti-resonant fiber (ARF) is designed and analyzed by the finite element method (FEM). All the structural parameters are optimized to achieve high-sensitivity liquid refractive index detection.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!