Repairing peripheral nerve injury, especially long-range defects of thick nerves, is a great challenge in the clinic due to their limited regeneration capability. Most FDA-approved nerve guidance conduits with large hollow lumen are only suitable for short lesions, and their effects are unsatisfactory in repairing long gaps of thick nerves. Multichannel nerve guidance conduits have been shown to offer better regeneration of long nerve defects. However, existing approaches of fabricating multichannel nerve conduits are usually complicated and time-consuming. Inspired by the intelligent responsive shaping process of shape memory polymers, in this study, a self-forming multichannel nerve guidance conduit with topographical cues was constructed based on a degradable shape memory PLATMC polymer. With an initial tubular shape obtained by a high-temperature molding process, the electrospun shape memory nanofibrous mat could be temporarily formed into a planar shape for cell loading to realize the uniform distribution of cells. Then triggered by a physical temperature around 37 °C, it could automatically restore its permanent tubular shape to form the multichannel conduit. This multichannel conduit exhibits better performance in terms of cell growth and the repair of rat sciatic nerve defects. These results reveal that self-forming nerve conduits can be realized based on shape memory polymers; thus, the fabricated bioinspired multichannel nerve guidance conduit has great potential in peripheral nerve regeneration.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acsnano.0c03570 | DOI Listing |
J Acoust Soc Am
December 2024
Department of Biomedical Engineering, University of Rochester, Rochester, New York 14620, USA.
Profile-analysis experiments measure the ability to discriminate complex sounds based on patterns, or profiles, in their amplitude spectra. Studies of profile analysis have focused on normal-hearing listeners and target frequencies near 1 kHz. To provide more insight into underlying mechanisms, we studied profile analysis over a large target frequency range (0.
View Article and Find Full Text PDFJ Clin Med
December 2024
Department of Obstetrics and Gynecology, Bern University Hospital, University of Bern, 3010 Bern, Switzerland.
: Postsurgical lower urinary tract dysfunction (LUTD) is a common problem following deep infiltrating endometriosis (DIE) resection. The condition may be caused either by surgically induced damage to the bladder innervation or by pre-existing endometriosis-associated nerve damage. The aim of this study is to evaluate the efficacy of preoperative and postoperative multichannel urodynamic testing (UD) in identifying pre-existing or surgically induced LUTD among patients with DIE.
View Article and Find Full Text PDFAdv Sci (Weinh)
December 2024
State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-Sen University, Guangzhou, 510006, China.
The real-time monitoring of in vivo electrophysiological and biochemical signals provides critical insights into the activities of tissues and organs. As the activity and metabolic state of different sites in the muscle vary, multichannel detection is necessary to capture the functional state of the whole muscle, yet the access to the bio-information in subcutaneous space remained challenging. This work reports the development of a reconfigurable microneedle electrode array integrated system designed to achieve painless and minimally invasive monitoring of subcutaneous electromyogram (EMG), oxygen species, and pH through an array of thumbtack-shaped microneedle (TSMN) electrode.
View Article and Find Full Text PDFNeural Netw
March 2025
Beijing Institute of Functional Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing 100053, China. Electronic address:
In neuroscience, phase synchronization (PS) is a crucial mechanism that facilitates information processing and transmission between different brain regions. Specifically, global phase synchronization (GPS) characterizes the degree of PS among multivariate neural signals. In recent years, several GPS methods have been proposed.
View Article and Find Full Text PDFNeuroimage
December 2024
BABA Center, Pediatric Research Center, Children's Hospital, University of Helsinki and Helsinki University Hospital, Helsinki, Finland; Department of Physiology, University of Helsinki, Helsinki, Finland. Electronic address:
Objective: Electroencephalography (EEG) is widely used for assessing infant's brain activity, and multi-channel recordings support studies on functional cortical networks. Here, we aimed to assess how the number of recording electrodes affects the quality and level of details accessible in studying infant's cortical networks.
Methods: Dense array EEG recordings with 124 channels from N=20 infants were used as the reference, and lower electrode numbers were subsampled to simulate recording setups with 63, 31, and 19 electrodes, respectively.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!