A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Spring-Assisted Distraction Osteogenesis for the Treatment of Shunt-Induced Craniosynostosis. | LitMetric

Shunt-induced craniosynostosis is a rare complication of ventricular shunting for hydrocephalus in pediatric patients. Although the exact pathophysiology of this form of secondary craniosynostosis is not well understood, the current understanding is that persistent drainage of the ventricular shunt causes decreased dural tension, resulting in decreased expansile force on the cranium and premature sutural fusion. Due to the low incidence of this complication, there is no consensus on the ideal treatment for shunt-induced craniosynostosis. In recent years, distraction osteogenesis has been employed with greater frequency, as it is felt to counter the fundamental problem of decreased expansile force on the cranium. However, in a patient with a ventricular shunt, placement of external hardware in close proximity to the shunt could cause significant morbidity due to the increased risk of shunt infection. We present the management of a patient with shunt-induced craniosynostosis who continued to be shunt-dependent. We chose to use fully buried springs to create an expansile force on the cranium as an alternative to external distractors so as to mitigate the risk of infection. We demonstrate that spring-assisted distraction osteogenesis can be an effective treatment modality for patients with shunt-induced craniosynostosis. This method should be considered in patients with contraindications to external distraction devices, such as ongoing shunt dependency.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1055665620947617DOI Listing

Publication Analysis

Top Keywords

shunt-induced craniosynostosis
20
distraction osteogenesis
12
expansile force
12
force cranium
12
spring-assisted distraction
8
treatment shunt-induced
8
ventricular shunt
8
decreased expansile
8
craniosynostosis
6
shunt-induced
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!