Biomechanical Comparison of Graft Preparation Techniques for All-Inside Anterior Cruciate Ligament Reconstruction.

Orthop J Sports Med

Division of Orthopaedics, Department of Surgery, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada.

Published: July 2020

Background: All-inside anterior cruciate ligament reconstruction (ACLR) is an emerging technique used to treat ACL injuries. The all-inside technique uses a 4-stranded graft made from a single tendon that is looped on itself. The 4 strands of the graft must be secured to each other to become a closed-loop structure. Various suture configurations exist to secure the graft to adjustable loop devices, and there is a lack of data to support one technique over another. In addition to the primary sutures used to fasten the graft together, accessory sutures can be tied over the button as secondary fixation.

Purpose: To evaluate biomechanical properties of 4-stranded grafts prepared in 5 different configurations.

Study Design: Controlled laboratory study.

Methods: Porcine flexor tendons (N = 25) were prepared in 5 different configurations (n = 5 tendons per group): simple-interrupted sutures (unsecured fixation), side-to-side fixation with and without secondary fixation, and end-to-end fixation with and without secondary fixation. The grafts were put through the same mechanical testing protocol (cyclic loading, pull to failure) to measure average load at graft failure, average displacement at failure, average stiffness, and average elongation rate. Differences between graft preparation techniques were investigated using 1-way analyses of variance (ANOVAs) with post hoc tests ( < .05).

Results: Significant 1-way ANOVAs for each biomechanical property were found. Unsecured fixation was the weakest graft preparation with the lowest stiffness (167 ± 12 N/mm), lowest ultimate failure load (637 ± 99 N), and highest elongation rate (0.0033 ± 0.0007 mm/s). End-to-end fixation without secondary fixation showed the highest ultimate failure load (846 ± 26 N), highest stiffness (212 ± 10 N/mm), and lowest rate of elongation (0.0025 ± 0.0001 mm/s). End-to-end fixation, both with and without secondary fixation, as well as side-to-side fixation with secondary fixation showed significantly higher ultimate failure loads than grafts with unsecured fixation. End-to-end fixation performed better than side-to-side fixation; however, for most variables, the difference was not statistically significant. Secondary fixation did not provide significant improvement.

Conclusion: The all-inside ACL graft with simple-interrupted sutures is biomechanically inferior to a graft that has its free ends secured to the adjustable tibial loop. Adding secondary fixation to the tibial button does not significantly change the biomechanical properties. Further clinical studies are required to determine whether these findings translate into differences in clinical outcome.

Clinical Relevance: All-inside ACLR is gaining popularity in hamstring ACL reconstructive techniques. These results provide surgeons with guidance on the best graft preparation method when using a single quadrupled hamstring tendon graft.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7383687PMC
http://dx.doi.org/10.1177/2325967120938039DOI Listing

Publication Analysis

Top Keywords

secondary fixation
28
fixation secondary
20
fixation
17
graft preparation
16
end-to-end fixation
16
graft
12
unsecured fixation
12
side-to-side fixation
12
ultimate failure
12
preparation techniques
8

Similar Publications

Background: Achilles tendon rupture is a common orthopedic injury, with an annual incidence of 11-37 per 100000 people, significantly impacting daily life. Minimally invasive surgery, increasingly favored for its reduced risks and comparable fixation strength to open surgery, addresses these challenges. Despite advantages like accelerated recovery, perioperative care poses emotional support, pain management, and rehabilitation challenges, impacting treatment efficacy and patient experience.

View Article and Find Full Text PDF

Knee pain in patients often involves varus deformity and unicompartmental osteoarthritis (OA). High tibial valgus osteotomy (HTO) is increasingly recognized as an effective treatment, as it realigns the knee's mechanical axis towards the healthier lateral compartment, delaying degenerative changes in the medial compartment and reducing the need for joint replacement. This case report discusses two patients with bilateral knee arthritis and varus deformity who underwent medial opening-wedge high tibial osteotomy (MOWHTO) using Dr.

View Article and Find Full Text PDF

Case: A 35-year-old man with morbid obesity sustained an ultra-low velocity (ULV) rotational knee dislocation secondary to a fall from standing. The patient was successfully treated using a subcutaneous knee-spanning internal fixator, the "INFIX" technique, which has previously been described for pelvic ring injuries.

Conclusion: This novel technique maintained the stable reduction of an ULV knee dislocation in a patient with morbid obesity until adequate healing was achieved.

View Article and Find Full Text PDF

Comparing dislocation force between a flanged haptics IOL and a harpoon haptics IOL.

Sci Rep

December 2024

Vienna Institute for Research in Ocular Surgery (VIROS), A Karl Landsteiner Institute, Hanusch Hospital, Vienna, Austria.

To compare two different secondary IOL fixation techniques, either flanged or hooked, regarding the least required force to dislocate the haptic in human corneoscleral donor tissue (CST). Experimental laboratory investigation. The least required dislocation force (LRDF) of two different fixation techniques, namely the flanged haptics (FH, as described by Yamane) and the harpoon haptic technique (HH, as described by Carlevale) were investigated using 20 three-piece IOLs (KOWA PU6AS) and 20 single-piece IOLs (SOLEKO CARLEVALE) fixated to human scleral tissue.

View Article and Find Full Text PDF

Purpose: To evaluate the outcomes of scleral-fixated intraocular lenses (IOLs) implanted using either Yamane technique or Gore-Tex suture fixation, in comparison to intracapsular lens fixation, and to assess the efficacy of various lens formulas in achieving predicted refractive targets.

Patients And Methods: This study included 45 eyes from 44 patients with scleral-fixated IOLs, comprising 37 Yamane eyes and 8 Gore-Tex eyes. Preoperative refractive predictions from various formulae were compared with final postoperative refraction.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!