Clinical utility of oximetric parameters to identify a high-risk phenotype of moderate-severe Obstructive Sleep Apnea (OSA).

Clin Respir J

Centro de Enfermedades Respiratorias y grupo de estudio trastornos respiratorios del sueño (GETRS), Clínica Las Condes, Santiago, Chile.

Published: December 2020

Unlabelled: It is unclear if oximetric parameters, such as total time of SpO < 90%, (T90), oxygen desaturation index-3% (ODI), minimum SpO , are able to describe a high-risk subtype of cardiovascular (CV) comorbidities in patients with Obstructive sleep apnea (OSA) beyond the apnea-hypopnea index.

Objective: To analyzed oximetric variables in patients with moderate-severe OSA to assess their predictive value regarding as hypertension, type 2 diabetes mellitus (T2DM), coronary heart disease (CHD) and CV mortality.

Methods: Using data from SantOSA cohort, we develop receiver operating characteristic curve and area under the curve (AUC) for each parameter, defining the proposed cutoff point in a training set. Then, in a validation set with a 5 years follow-up, we evaluate the clinical differences between groups using the proposed cutoff. We also calculated adjusted Hazard Ratios (HR) of mortality using a Cox regression model.

Results: About 965 patients with moderate-severe OSA (525 in training and 440 in validation group) were included. The best AUC was achieved with T90 (AUC = 0.66) and ODI (AUC = 0.61). Proposed cutoffs of T90 were hypertension: 10%, T2DM: 20%, CHD: 15%, meanwhile, proposed cutoff of ODI was ≥ 30 ev for hypertension and T2DM. Regarding CV mortality, T90 ≥ 20% was independently associated with an adjusted HR 2.44 (CI, 1.21-4.94), P-value = 0.01, meanwhile, ODI ≥ 30 ev. reported and adjusted HR 1.59 (CI, 0.75-3.39), P-value = 0.22.

Conclusion: In patients with moderate-severe OSA, oximetric parameters, especially T90 ≥ 20% remained a predictor of mortality after adjusting for a range of demographic and disease predictors.

Download full-text PDF

Source
http://dx.doi.org/10.1111/crj.13256DOI Listing

Publication Analysis

Top Keywords

clinical utility
4
utility oximetric
4
oximetric parameters
4
parameters identify
4
identify high-risk
4
high-risk phenotype
4
phenotype moderate-severe
4
moderate-severe obstructive
4
obstructive sleep
4
sleep apnea
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!