Purpose: More than 7 million Americans who have diabetes use insulin therapy. The majority continue to use syringes and vials or traditional insulin pens to deliver their insulin doses. Using these tools to deliver insulin presents numerous challenges for both the person with diabetes and their clinicians. This article provides an in-depth introduction to a new category of insulin delivery devices and integrated management systems, referred to as smart insulin pens. The article includes information about how these integrated insulin delivery systems can reduce many of the challenges of rapid-acting insulin dosing via injection by enabling easier and more accurate dose recording, dose calculations, and sharing of diabetes management data with clinicians. This article also discusses new roles for diabetes care and education specialists in diabetes data-driven care and practice and addresses how smart insulin pens represent one of many newer digital diabetes management tools that can assist people with diabetes and their clinicians to optimally achieve and deliver quality, data-driven diabetes care.
Conclusions: Newer and simplified insulin delivery devices with their integrated management systems, such as smart insulin pens, have the potential to minimize the challenges and complexities associated with insulin injection therapy while also providing people with diabetes and their clinicians more complete and integrated data in easily transmitted reports that support more efficient data analysis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/0145721720930183 | DOI Listing |
Animals (Basel)
January 2025
School of Agriculture and Food Sustainability, The University of Queensland, Gatton, QLD 4343, Australia.
The extent of endocrine changes in response to various levels of heat stress and subsequent recovery is not well understood. Two cohorts of 12 Black Angus steers were housed in climate-controlled rooms (CCR) and subjected to three thermal periods: PreChallenge (5 d), Challenge (7 d) and Recovery (5 d). PreChallenge and Recovery provided thermoneutral conditions.
View Article and Find Full Text PDFHealthcare (Basel)
December 2024
Endocrinology Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, 20122 Milan, Italy.
The management of type 1 diabetes in pregnancy with new technologies is challenging. Sometimes the complexity of new-generation systems such as "continuous subcutaneous insulin infusion, CSII" and patient or provider preference do not allow their use, so women with type 1 diabetes in pregnancy continue to be treated with subcutaneous multiple-injection insulin therapy using pens. Smart insulin pens are new tools that allow for data collection on insulin dose and time of administration and have additional connectivity features.
View Article and Find Full Text PDFPoult Sci
December 2024
Department of Biochemistry, College of Sciences, King Saud University, Riyadh, Saudi Arabia.
This study evaluated the effect of wheat germ oil (WGO), Bacillus subtilis, and their combination on growth performance, immune response, nutrient digestibility, intestinal microbial, oxidative status, and gene expression in heat-stressed broilers. Four hundred one-day-old male Ross 308 broilers were distributed into five pens (20 birds/pen) in four experimental groups: a control (CON) without additives, WGO group fed diet with WGO at 200 mg.kg, BS group fed diet with B.
View Article and Find Full Text PDFAnimals (Basel)
December 2024
Department of Animal Science, Faculty of Agricultural and Veterinary Sciences, São Paulo State University, Jaboticabal 14884-900, SP, Brazil.
The objective of this study was to evaluate the effect of 3-nitrooxypropanol (3-NOP) in combination with different feed additives on growth performance, carcass traits, meat quality, enteric methane (CH) emissions, nutrient intake and digestibility, and blood parameters in feedlot beef cattle. In experiment (Exp.) 1, one hundred sixty-eight Nellore bulls (initial bodyweight (BW) 410 ± 8 kg) were allocated to 24 pens in a completely randomized block design.
View Article and Find Full Text PDFAm J Nurs
January 2025
Brenna Frankish is the clinical learning programs coordinator at Children's Healthcare of Atlanta, where Kristina Amplo is the campus education coordinator and Christina Calamaro is the director of nursing research and evidence-based practice for nursing and allied health. Rachael Townsend is the pediatric program manager at Wellstar Health System in Marietta, GA. Tonya Miller-Roberts is a clinical psychologist at the Atlanta VA Medical Center in Decatur, GA. Akane Fujimoto Wakabayashi is a graduate research assistant at the Georgia Institute of Technology in Atlanta. This study was supported through funding from Owen Mumford, Ltd, which also supplied the active safety pen needle devices used. Contact author: Brenna Frankish, . The authors have disclosed no potential conflicts of interest, financial or otherwise.
Background: Insulin pens are the mainstay of insulin delivery in the pediatric population, especially among patients unable to use an insulin pump. Safety pen needle (SPN) devices have been embraced by both nurses and patients because they limit the risks of needlestick injury and exposure to blood-borne pathogens. With the commonly used traditional passive SPN device, however, it can be difficult to observe that the dose has been accurately or fully administered.