Purpose: Ultrasound grayscale imaging preset optimization has often been qualitative and dependent upon vendor application specialists. This study aimed to propose a systematic approach for grayscale imaging preset optimization and apply the approach in a clinical abdominal scan setting.

Methods: A six-step approach was detailed including identification of clinical task, adjustment of basic parameters, fine-tuning of advanced parameters, image performance metrics confirmation, clinical evaluation and data analysis, and implementation of new presets and monitoring of clinical usage. Its application in an abdominal scanning task was described for each step with phantoms, volunteers, and software tools.

Results: Clinical image data analytics facilitated the understanding of the imaging task, relevant transducers, and target characteristics, in addition to specific requests from radiologists. Quantitative measurements were made on global image contrast and gray map function. In addition, clinically relevant phantoms and volunteer scans without and with acoustic distortion layers were involved to determine the new presets. Furthermore, phantom signal to noise ratio study and clinical evaluation using volunteers with different body habitus were utilized to confirm the superiority of the new presets. Quantitative clinical usage monitoring demonstrated successful implementation of the new presets.

Conclusions: A systematic approach for grayscale imaging preset optimization has been proposed and successfully applied for a specific clinical task. This approach was designed to be generalizable and relatively flexible, which would facilitate movement away from previous qualitative and subjective approaches.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7592964PMC
http://dx.doi.org/10.1002/acm2.13000DOI Listing

Publication Analysis

Top Keywords

grayscale imaging
16
imaging preset
12
preset optimization
12
ultrasound grayscale
8
application abdominal
8
abdominal scanning
8
systematic approach
8
approach grayscale
8
clinical
8
clinical task
8

Similar Publications

Background: Recurrent pregnancy loss (RPL) poses significant challenges in clinical management due to an unclear etiology in over half the cases. Traditional screening methods, including ultrasonographic evaluation of endometrial receptivity (ER), have been debated for their efficacy in identifying high-risk individuals. Despite the potential of artificial intelligence, notably deep learning (DL), to enhance medical imaging analysis, its application in ER assessment for RPL risk stratification remains underexplored.

View Article and Find Full Text PDF

Ultrasound radiomics model based on grayscale transrectal ultrasound-guided biopsy for diagnosing prostate cancer and predicting distant metastasis.

Int Urol Nephrol

January 2025

Department of Ultrasound, The First College of Clinical Medical Science, China Three Gorges University, Yichang Central People's Hospital, No. 2 Jiefang Road, Xiling District, Yichang, Hubei, China.

Objective: A prostate ultrasound (US) imaging omics model was established to assess its effectiveness in diagnosing prostate cancer (PCa), predicting Gleason score (GS), and determining the likelihood of distant metastasis.

Methods: US images of patients with prostate pathology confirmed by biopsy or surgery at our hospital were retrospectively analyzed. Regions of interest (ROI) segmentation, feature extraction, feature screening, and the construction and training of the radiomics model were performed.

View Article and Find Full Text PDF

Machine Learning and GLCM Analysis for Enhanced AMD Detection in Retinal Image.

Biomed Phys Eng Express

January 2025

Department of Electronics and Communication Engineering, SRM Institute of Science and Technology (Deemed to be University) College of Engineering & Technology, Kattankulathur Campus, Chengalpattu District,, Kattankulathur, 603203, INDIA.

Global blindness is substantially influenced by age-related macular degeneration (AMD). It significantly shortens people's lives and severely impairs their visual acuity. AMD is becoming more common, requiring improved diagnostic and prognostic methods.

View Article and Find Full Text PDF

Multispectral transmission imaging has emerged as a promising technique for imaging breast tissue with high resolution. However, the method encounters challenges such as low grayscale, noisy transmission images with weak signals, primarily due to the strong absorption and scattering of light in breast tissue. A common approach to improve the signal-to-noise ratio (SNR) and overall image quality is frame accumulation.

View Article and Find Full Text PDF

Background: The diagnostic challenges presented by hyperchromatic crowded cell groups (HCGs) in cervical cytology often result in either overdiagnosis or underdiagnosis due to their densely packed, three-dimensional structures. The objective of this study is to characterize the structural differences among HSIL-HCGs, AGC-HCGs, and NILM-HCGs using quantitative texture analysis metrics, with the aim of facilitating the differentiation of benign from malignant cases.

Methods: A total of 585 HCGs images were analyzed, with assessments conducted on 8-bit gray-scale value, thickness, skewness, and kurtosis across various groups.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!