A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Assembly of "carrier free" enzymatic nano-reporters for improved ELISA. | LitMetric

Assembly of "carrier free" enzymatic nano-reporters for improved ELISA.

Analyst

School of Basic Medical Sciences, Guangxi Medical University, Nanning, Guangxi 530021, China.

Published: October 2020

Enzyme-linked immunosorbent assay (ELISA) is an economic and easy operation technique that has been widely used for the detection of protein in industry. However, the low loading capacity of the enzyme reporter has contributed to the low sensitivity of traditional ELISA, and the cross-linking procedures of the enzyme-labeled antibody in ELISA methods can lead to the inactivation of the enzyme, which will further decrease the sensitivity. To address this issue, herein we fabricated "carrier-free" nanoparticles to obtain a horseradish peroxidase (HRP) labelled reporter with a high HRP loading capacity. A disulphide-containing bis-N-hydroxy succinimide (NHS) crosslinker (NHS-SS-NHS) was used to control the link and release of traceless HRPs, thus without reduction of its enzymatic activity. The HRP nanoparticle (NanoHRP) was successfully applied for dot blotting and ELISA. When carcinoembryonic antigen (CEA) was used as a target, the detection limit of the NanoHRP-based ELISA was 0.005 ng mL, which was about 400 times more sensitive than traditional ELISA. A good correlation between the CEA concentrations and the response values measured by NanoHRP ELISA was obtained in the range of 0.005 to 1 ng mL. This concept could be exploited to improve ELISA tests, especially those requiring a high accuracy, to facilitate physicians in deciding the appropriate medical treatment.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d0an00585aDOI Listing

Publication Analysis

Top Keywords

elisa
9
loading capacity
8
traditional elisa
8
assembly "carrier
4
"carrier free"
4
free" enzymatic
4
enzymatic nano-reporters
4
nano-reporters improved
4
improved elisa
4
elisa enzyme-linked
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!