A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@remsenmedia.com&api_key=81853a771c3a3a2c6b2553a65bc33b056f08&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Individual and Simultaneous Voltammetric Determination of Ultra-Trace Environmental Contaminant Dihydroxybenzene Isomers Based on a Composite Electrode Sandwich-like Structure. | LitMetric

An advanced electroanalytical technique for the simultaneous assessment of environmental contaminant dihydroxybenzene isomers, catechol (CC), hydroquinone (HQ), and resorcinol (RC), has been investigated using palladium nanoparticles (PdNPs) incorporated onto a poly(1,5-diaminonaphthalene) (DAN) matrix over a glassy carbon electrode (GCE). Concurrently, these types of phenols can be assessed by the PdDAN/GCE modified electrode employing square wave voltammetry and cyclic voltammetry (CV) techniques under optimal conditions. This modified electrode has demonstrated linear responses for CC, HQ, and RC from 50.0 to 1000.0 mM; concomitantly, low detection limits of 0.22, 0.22, and 0.47 nM and low quantification limits of 0.740, 0.758, and 1.590 nM, have been, respectively, shown. Successfully, the simultaneous assessment of the three isomers in river stream water, tap water, and underground water has been implemented via the modified electrode under investigation. In comparison to reported studies, the PdDAN catalytic electrode has shown an effective sensitivity, leverage reproducibility, long-term stability, and excellent anti-interference capability for the determination of dihydroxybenzene isomers.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7408232PMC
http://dx.doi.org/10.1021/acsomega.0c02228DOI Listing

Publication Analysis

Top Keywords

dihydroxybenzene isomers
12
modified electrode
12
environmental contaminant
8
contaminant dihydroxybenzene
8
simultaneous assessment
8
electrode
6
individual simultaneous
4
simultaneous voltammetric
4
voltammetric determination
4
determination ultra-trace
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!