Background: The knowledge of normal anatomy of glenoid in a population has relevance in terms of comparison with other regional and national population. Furthermore, it could enable clinicians to judge whether the available sizes of reverse total shoulder arthroplasty (RTSA) prosthesis could provide optimal fit for the glenoid in Indian patients.

Methods: We evaluated consecutive 200 3-dimensional chest CT scans of 50 male and 50 female patients which included both shoulder joints and done for non-orthopaedic diseases at a tertiary care institute. The glenoid height, width, and version were measured using commercially available computer program.

Results: Mean age of the patents was 38.6 ± 13.8 years (range, 19-59 years). The mean glenoid height was 33.9 ± 3.1 mm and maximum glenoid width was 24.2 ± 2.1 mm. Mean glenoid version in the study population was a retroversion of 3.47 ± 4.7. The maximum glenoid width of 45% female and 15% male patients was less than 25 mm which is the diameter of smallest available glenoid baseplate among the commonly used RTSA systems.

Conclusions: The normal glenoid size of a large cohort of Indian population studied was smaller than that reported in cohorts from western countries. The glenoid width of substantial proportion of patients, especially female patients, was less than the diameter of smallest available glenoid baseplate. Clinical studies are needed in future in Indian patients undergoing RTSA to evaluate the glenoid bone-baseplate mismatch and ascertain the necessity of development of smaller size glenoid baseplate for optimal prosthesis fit in Indian patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7394810PMC
http://dx.doi.org/10.1016/j.jcot.2020.03.001DOI Listing

Publication Analysis

Top Keywords

glenoid
14
glenoid width
12
glenoid baseplate
12
reverse total
8
total shoulder
8
shoulder arthroplasty
8
female patients
8
glenoid height
8
maximum glenoid
8
diameter smallest
8

Similar Publications

Unlabelled: Introduction-Aim: Full-polyethylene glenosphere reverse shoulder arthroplasty (FP-RSA) known commonly as inverted-bearing concept utilizes a polyethylene glenosphere and metallic humeral liner. The aim was to assess mid-term outcomes of FP-RSA focusing on the incidence of scapular notching.

Methods: A retrospective analysis of 24 consecutive primary FP-RSA performed between 2017 and 2020 was conducted.

View Article and Find Full Text PDF

In the young, active patient with osteoarthritis, the optimal treatment of B2 glenoid morphology remains a subject of continued debate. Current treatment options have specific advantages and disadvantages. These treatments include hemiarthroplasty with or without glenoid reaming, total shoulder arthroplasty (TSA) with or without eccentric reaming, TSA with bone graft or posteriorly augmented glenoid implant, and reverse TSA.

View Article and Find Full Text PDF

A radiopaque protuberance of the glenoid fossa.

Oral Surg Oral Med Oral Pathol Oral Radiol

December 2024

Department of Surgery, Division of Oral and Maxillofacial Surgery, University of Cincinnati School of Medicine, Cincinnati, OH. Electronic address:

View Article and Find Full Text PDF

Background: While outcomes following reverse shoulder arthroplasty (rTSA) have often been gauged through radiological assessments focusing on prosthesis position, there is increasing recognition of patient-reported outcomes, particularly satisfaction, as indicators of surgical success. The objective of this study was to correlate radiological findings with clinical outcomes, patient satisfaction, and health-related quality of life (HRQoL).

Materials And Methods: A retrospective evaluation was conducted on patients following rTSA at a minimum of two years postoperatively.

View Article and Find Full Text PDF

Background: Surgical planning for anterior shoulder instability (ASI) necessitates accurate measurements of glenoid bone defects, but current methods are either challenging or too complex for practical use. This underscores the need for a simplified, but precise, assessment technique for anterior glenoid bone defects.

Purpose: To introduce a new measurement technique that requires only computed tomography (CT) of the affected shoulder joint and simultaneously simplifies the assessment of bone defects in the anterior glenoid.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!