Case: We present a case of a 56-year-old man who sustained a basal cervical periprosthetic fracture around a well-fixed metal-on-metal hip resurfacing arthroplasty (MoMHRA). Although several fixation methods have been described, there seems to be no consensus about the optimal fixation method for fractures around MoMHRAs. This fracture could be regarded as a Vancouver type-B1 or -C periprosthetic fracture, so we successfully treated our patient in a standard way with a dynamic hip screw (DHS) and one cannulated hip screw.

Conclusion: We describe DHS fixation as a successful treatment option for periprosthetic hip fractures around well-fixed MoMHRA.

Download full-text PDF

Source
http://dx.doi.org/10.2106/JBJS.CC.19.00540DOI Listing

Publication Analysis

Top Keywords