Background: Clinical series have been published using the configuration of 2 intercarpal Kirschner wires (K-wires) adjacent to the fracture being connected, but biomechanical analysis is lacking. The objective of this pilot biomechanical study was to model and compare the effects of externally connecting 2 intermetacarpal K-wires for the stabilization of transverse metacarpal shaft fractures. Our research hypothesis was that the connected constructs would be stiffer than the unconnected K-wires.

Methods: A 3-dimensional computer-based model of small finger transverse metacarpal fracture stabilization was designed with 3 transverse 1.1 mm K-wires being anchored to the adjacent metacarpal. Three arrangements were tested: all 3 K-wires in parallel, the middle K-wire angled toward the proximal wire, and the middle angled K-wire being rigidly fixed to the proximal K-wire. The proximal wire was proximal to the fracture. A finite element analysis was performed by applying a cantilever force of 100 N at the head of the metacarpal. The metacarpal was considered to be uniform in composition with parameters typical for human bone. Kirschner wire parameters for stainless steel were used. Force (N) versus displacement was measured.

Results: The configuration with the middle angled K-wire being rigidly fixed to the proximal K-wire showed greater stiffness (12 N/mm) than nonattached constructs. The connected construct was 2.3 times more stiff than the unattached parallel construct and 2.5 times more stiff than angling the middle K-wire without attachment.

Conclusions: In a computer model simulation, our results show that attaching 2 K-wires adjacent to the fracture provides more than twice the stiffness of unconnected K-wires.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9112730PMC
http://dx.doi.org/10.1177/1558944720946485DOI Listing

Publication Analysis

Top Keywords

connecting intermetacarpal
8
intermetacarpal k-wires
8
metacarpal shaft
8
shaft fractures
8
k-wires adjacent
8
adjacent fracture
8
transverse metacarpal
8
middle k-wire
8
proximal wire
8
middle angled
8

Similar Publications

This study aims to analyze the changes in dermal thickness in patients with systemic scleroderma (SSc) in comparison with normal skin and also compare clinical forms with diffuse and limited cutaneous involvement. The study group consisted of female patients diagnosed with SSc with a disease history not exceeding 5 years. The areas of interest for ultrasound examination included the proximal phalanx of the third finger, the second intermetacarpal space, and the extension surface of the lower third of the forearm.

View Article and Find Full Text PDF
Article Synopsis
  • - The study aimed to characterize a previously unreported ligamentous structure called the distal dorsal intermetacarpal ligament, which connects the metacarpal heads of the long fingers in the dorsal intermetacarpal spaces.
  • - Twenty-five hands were dissected, revealing this ligament in every case, along with measurements taken for size and position, and analyses conducted via histology and ultrasound.
  • - The results showed that this ligamentous structure stabilizes the metacarpal heads, particularly at the second and fourth spaces, by limiting excessive movement (hyperabduction).
View Article and Find Full Text PDF

Case: A 20-year-old woman presented with painful, snapping extensor pollicis longus (EPL) tendon subluxation and trapeziometacarpal (TMC) joint instability. Hemi-extensor carpi radialis longus (ECRL) tendon autograft stabilized the TMC joint, reconstructing the 1-2 intermetacarpal ligament. The subluxed EPL tendon was centralized over the dorsal first metacarpal by tightening the metacarpophalangeal radial sagittal band and creating a dorsal first metacarpal "neosheath" pulley using ECRL graft remnant.

View Article and Find Full Text PDF

Background: Clinical series have been published using the configuration of 2 intercarpal Kirschner wires (K-wires) adjacent to the fracture being connected, but biomechanical analysis is lacking. The objective of this pilot biomechanical study was to model and compare the effects of externally connecting 2 intermetacarpal K-wires for the stabilization of transverse metacarpal shaft fractures. Our research hypothesis was that the connected constructs would be stiffer than the unconnected K-wires.

View Article and Find Full Text PDF

Prevalence of the extensor digitorum, extensor digiti minimi and extensor indicis tendons and their variations.

Hand Surg Rehabil

September 2020

Department of Anatomy, Faculty of Medicine, Suleyman Demirel University, Çünür, Süleyman Demirel Cd, 32260 Merkez/Isparta, Turkey. Electronic address:

We aimed to investigate tendon variations of the extensor digitorum (ED), extensor digiti minimi (EDM), and extensor indicis proprius (EIP) muscles. Our study was performed on 43 fetal cadavers (86 extremities), aged between 17 and 40 weeks of gestation. The number of ED tendons varied from three to six, proximal to the extensor retinaculum (ER), and from three to eight, distal to the ER.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!