Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The use of psychoactive substances has been associated with increased risk for traffic accidents. Hair testing has become a routine practice in clinical and forensic toxicological laboratories, with a unique perspective in the investigation of drug consumption. The study aimed to develop and validate a UHPLC-MS/MS method for the determination of multiple drugs in hair, to be used for toxicological examination in driving license granting. Sample preparation was a one-step liquid extraction of milled hair with methanol, which was incubated for 15h at 50°C. The chromatographic separation was performed in a reversed phase column, with a run time of 2.2min. Measured compounds were cocaine, benzoylecgonine, norcocaine, anhydroecgonine methyl ester, cocaethylene, amphetamine, methamphetamine, methylenedioxyamphetamine, methylenedioxymethamphetamine, fenproporex, amfepramone, mazindol, codeine, morphine, 6-monoacetylmorphine, and tetrahydrocannabinol. The assay was linear for all substances (r>0.99), accurate (86.63-105.87 %), and precise, with a cv ranging from 1.9-13.5 % for intra-assay and 3.3-14.3 % for inter-assay. There was no significant carry over effect and the internal standard corrected matrix effect was minimal. The relative uncertainty percentages were below 9% for all the substances at cut-off values. The method was successfully applied to 50 hair samples from injured drivers, with 12% of positivity, including cocaine, MDMA and THC.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.forsciint.2020.110428 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!