Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Large numbers of rodents are often used in the study of disease progression and in the evaluation of its potential treatments. To avoid subjective observation and to minimize home cage interference, we developed a computerized home cage monitoring system (HCMS100) based on a standard cage rack adapted with a single laser beam and a detector mounted on each cage, enabling to monitor mice movements based on laser beam interruptions. This retrofit system provided continuous and uninterrupted monitoring of spontaneous movement of a group of mice in a home cage. Validity was evaluated using disease state induced by LPS modelling bacterial infection and by influenza virus. RESULTS: Spontaneous activity of different number of mice (2-8) per cage showed the expected circadian rhythm with increased activity during the night, and its extent dependent on the number of mice in the cage. Females and males show similar circadian rhythm. Intranasal LPS administration and pulmonary infection with live influenza virus resulted in major reduction of mice activity along disease progression. Increase in activity over time was a good indicator of the recovery process from both LPS exposure and the flu infection. CONCLUSIONS: HCMS100 was shown to be a reliable, inexpensive, easy to use system that requires no changes in the common housing of various experimental animals (mice, hamsters, rats etc.). With minimal intervention, HCMS100 provides a continuous record of group activity with clear pattern of circadian rhythm, allowing long term recording of home cage activity even in restricted access environments.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.lfs.2020.118214 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!