Purpose: To evaluate the optical quality and tear film quality in patients with dry eye syndrome (DES) before and after using an intranasal neurostimulation device to stimulate tear production.

Methods: Cross-sectional review of 33 eyes in 21 patients with DES who underwent optical quality and tear film analysis as part of their routine dry eye evaluation pre- and post-neurostimulation trial in office. Optical quality was assessed by measuring the objective scattering index (OSI) and modulation transfer function (MTF). The time to blink and mean tear film OSI were used to analyze the tear film.

Results: Optical quality after the use of the intranasal neurostimulator improved with an average decrease (improvement) in OSI of 0.30±0.68 (P=0.015) and an average increase (improvement) in MTF of 2.12±9.2 (P=0.15). Pre-intranasal neurostimulation OSI had a positive correlation with age (Spearman's rho 0.60, p < 0.001), while MTF had a negative correlation (Spearman's rho -0.38, p = 0.03). Pre-intranasal neurostimulation OSI had a negative correlation with MTF (Spearman's rho -0.85, p < 0.001) and a positive correlation with tear film mean OSI (Spearman's rho 0.85, p <0.001).

Conclusion: The optical quality of patients with DES is improved with the use of intranasal neurostimulation for tear production, and there was a trend towards improved MTF though not statistically significant. Future studies are needed to follow patients longitudinally.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7367722PMC
http://dx.doi.org/10.2147/OPTH.S255599DOI Listing

Publication Analysis

Top Keywords

optical quality
20
tear film
20
spearman's rho
16
quality tear
12
dry eye
12
film analysis
8
patients dry
8
eye syndrome
8
film osi
8
pre-intranasal neurostimulation
8

Similar Publications

Idiopathic intracranial hypertension (IIH) is a neurological disorder characterized by chronic headaches, cognitive difficulties, reduced quality of life, and rarely irreversible visual loss. Community diagnosis is often challenging due to unfamiliarity with current guidelines and a lack of clinical experience, leading to misdiagnosis and treatment delays, which can negatively impact visual recovery and quality of life. Our study examined the time to diagnosis and investigated the barriers to timely diagnosis in adults with newly diagnosed IIH.

View Article and Find Full Text PDF

Glaucoma Detection and Feature Identification via GPT-4V Fundus Image Analysis.

Ophthalmol Sci

November 2024

Division of Ophthalmology Informatics and Data Science, Viterbi Family Department of Ophthalmology, Shiley Eye Institute, University of California, San Diego, La Jolla, California.

Purpose: The aim is to assess GPT-4V's (OpenAI) diagnostic accuracy and its capability to identify glaucoma-related features compared to expert evaluations.

Design: Evaluation of multimodal large language models for reviewing fundus images in glaucoma.

Subjects: A total of 300 fundus images from 3 public datasets (ACRIMA, ORIGA, and RIM-One v3) that included 139 glaucomatous and 161 nonglaucomatous cases were analyzed.

View Article and Find Full Text PDF

Purpose: This study evaluated beam quality and radiation dosimetry of a CT scanner equipped with a novel detector and filtration technology called PureVision Optics (PVO). PVO features miniaturized electronics, a detector cut with microblade technology, and increased filtration in order to increase x-ray detection and reduce image noise.

Methods: We assessed the performance of two similar 320-detector CT scanners: one equipped with PVO and one without.

View Article and Find Full Text PDF

Purpose: The purpose of this work was to evaluate the image quality of a commercial CT scanner equipped with a novel detector and filtration technology called PureVision Optics (PVO).

Methods: CT number, noise, contrast-to-noise ratio (CNR), modulation transfer function (MTF), and noise power spectrum (NPS) were assessed using the ACR CT Accreditation phantom scanned with various acquisitions at 80 kV, 100 kV, 120 kV, and 135 kV, each with multiple CTDIvol values of 20 mGy, 40 mGy, and 65 mGy. Artifacts were evaluated in an anthropomorphic head phantom, a cadaver head, and in patient studies.

View Article and Find Full Text PDF

Interest in carbon dioxide (CO) sensors is growing rapidly due to the increasing awareness of the link between air quality and health. Indoor, high CO levels signal poor ventilation, and outdoor the burning of fossil fuels and its associated pollution. CO gas sensors based on integrated optical waveguides are a promising solution due to their excellent gas sensing selectivity, compact size, and potential for mass manufacturing large volumes at low cost.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!