Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Effects-directed analysis (EDA) is used to identify the principal toxic components within a complex mixture using iterative steps of chemical fractionation guided by bioassay results. Bioassay selection can be limited in EDA because of the volume requirements for many standardized test methods, and therefore, a reduced-volume acute toxicity test that also provides whole-organism responses is beneficial. To address this need, a static, 7-d, water-only, reduced-volume method (50 mL, 10 organisms) was developed for Hyalella azteca that substantially decreases the volume requirements of standard-volume acute test exposures (200-500 mL of test solution, 15-20 organisms) while maintaining water quality and meeting control survival criteria. Standard- and reduced-volume methods were compared by conducting concurrent toxicity tests with 2 inorganic toxicants (KCl and CdCl ) and 2 organic mixtures of naphthenic acid fraction components (NAFCs) to evaluate test performance. There was no difference between methods when comparing the median lethal concentrations (LC50s) for KCl and both NAFC mixtures (p > 0.05). The LC50s for CdCl were statistically different (p = 0.0002); however, this was not considered biologically meaningful because the difference between LC50s was <2-fold. In conclusion, the reduced-volume H. azteca test method generated results comparable to standard-volume test methods and is suitable for use in situations where limited testing material is available, such as when conducting EDA. Environ Toxicol Chem 2020;39:2221-2227. © Her Majesty the Queen in Right of Canada 2020. Reproduced with the permission of the Minister of Environment and Climate Change Canada.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7756806 | PMC |
http://dx.doi.org/10.1002/etc.4840 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!