Background: Amplification of viral ribonucleic acid (RNA) by real-time reverse transcriptase polymerase chain reaction (rRT-PCR) is the gold standard to detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Since the initial outbreak, strategies to detect and isolate patients have been important to avoid uncontrolled viral spread. Although testing capacities have been upscaled, there is still a need for reliable high throughput test systems, specifically those that require alternative consumables. Therefore, we tested and compared two different methods for the detection of viral PCR products: rRT-PCR and mass spectrometry (MS).

Methods: Viral RNA was isolated and amplified from oro- or nasopharyngeal swabs. A total of 22 samples that tested positive and 22 samples that tested negative for SARS-CoV-2 by rRT-PCR were analyzed by MS. Results of the rRT-PCR and the MS protocol were compared.

Results: Results of rRT-PCR and the MS test system were in concordance in all samples. Time-to-results was faster for rRT-PCR. Hands-on-time was comparable in both assays.

Conclusions: MS is a fast, reliable and cost-effective alternative for the detection of SARS-CoV-2 from oral and nasopharyngeal swabs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7472307PMC
http://dx.doi.org/10.3390/v12080849DOI Listing

Publication Analysis

Top Keywords

severe acute
8
acute respiratory
8
respiratory syndrome
8
syndrome coronavirus
8
coronavirus sars-cov-2
8
mass spectrometry
8
nasopharyngeal swabs
8
samples tested
8
rrt-pcr
6
detection severe
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!