Background: Limited data is available on the use of a polyester graft limb with a helical stent configuration deployed in the external iliac artery (EIA) during endovascular aneurysm repair (EVAR), so we prospectively analyzed the efficacy of the Zenith Spiral-Z limb deployed in the EIA.

Methods and results: Patients undergoing EVAR using a Zenith stent-graft and Spiral-Z limb deployed in the EIA were prospectively registered in 24 Japanese institutions from June 2017 to November 2017. In total, 65 patients (74 limbs) (mean age: 77.1±8.0 years, 87.7% men, mean abdominal aortic aneurysm (AAA) diameter: 51.9±7.2 mm, mean iliac artery aneurysm (IAA) diameter: 38.3±10.0 mm) were registered and followed up. The most common reason for deployment in the EIA was a common IAA (43 limbs, 58.1%), and 8 limbs (10.8%) had a bare nitinol stent placed at the Spiral-Z limb. A total of 61 patients (70 limbs) completed a 24-month follow-up. There were 2 Spiral-Z limb stenoses and 1 occlusion, leading to a primary patency of 95.5% and a secondary patency of 100%, at 24 months. Buttock claudication occurred in 24.3% of the limbs treated at 1 month but decreased to 4.3% at 24 months.

Conclusions: Our multicenter prospective study showed that Spiral-Z limb deployed in the EIA was associated with satisfactory results and seems to be a durable option, even in the era of iliac branch devices.

Download full-text PDF

Source
http://dx.doi.org/10.1253/circj.CJ-20-0195DOI Listing

Publication Analysis

Top Keywords

spiral-z limb
24
limb deployed
16
iliac artery
12
multicenter prospective
8
zenith spiral-z
8
deployed external
8
external iliac
8
endovascular aneurysm
8
aneurysm repair
8
deployed eia
8

Similar Publications

Purpose: Recent reports of the Zenith Alpha abdominal endovascular graft (Zenith Alpha AAA, Cook, Inc., Bloomington, Indiana) have demonstrated an unexpectedly high incidence of limb graft occlusion (LGO). The purpose of this study was to prospectively evaluate the performance of the Zenith AAA in Japan, with a specific focus on LGO.

View Article and Find Full Text PDF

Purpose: Zenith Alpha Abdominal (Cook Medical, Bloomington, IN, USA) is one of the new-generation low-profile stent-grafts with demonstrated satisfactory early and midterm clinical outcomes for endovascular treatment of abdominal aortic aneurysms (AAAs). The aim was to evaluate early and midterm results of this device in the framework of a multicenter regional retrospective registry, with the analysis of morphological factors affecting outcomes, including different limb configurations.

Materials And Methods: Between January 2016 and November 2021, 202 patients with AAA underwent elective endovascular aneurysm repair (EVAR) with implantation of a Zenith Alpha Abdominal in 7 centers.

View Article and Find Full Text PDF

One-Year Results of ZBIS Iliac Branch Device With an Off-Label Connection Limb.

J Endovasc Ther

June 2022

Department of Vascular Medicine, German Aortic Center Hamburg, University Heart Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.

Purpose: The purpose of this article is to study 1-year results of Zenith branch iliac endovascular graft (ZBIS) with the off-label use of a 13 mm spiral Z limb to connect to the aortic main body.

Materials And Methods: A retrospective review from 2015 to 2019 of all iliac branch devices (IBDs) was performed at 1 institution that were connected to an aortic main body with a 13 mm spiral Z limb and had at least 1-year follow-up with computed tomography (CT). Primary endpoints are freedom from ZBIS separation from the connection limb, endoleak (EL), or reintervention at 1 year.

View Article and Find Full Text PDF

Objectives: Intraprocedural deployment of endovascular devices during complex aortic repair with 2-dimensional (2D) x-ray fluoroscopic guidance poses challenges in terms of accurate delivery system positioning and increased risk of x-ray radiation exposure with prolonged fluoroscopy times, particularly in unfavorable anatomy. The objective of this study was to assess feasibility of using an augmented reality (AR) system to position and orient a modified aortic endograft delivery system in comparison with standard fluoroscopy.

Materials And Methods: The 3-dimensional guidance, navigation, and control (3D-GNC) prototype system was developed for eventual integration with the Intra-Operative Positioning System (IOPS, Centerline Biomedical, Cleveland, OH) to project spatially registered 3D holographic representations of the subject-specific aorta for intraoperative guidance and coupled with an electromagnetically (EM) tracked delivery system for intravascular navigation.

View Article and Find Full Text PDF

Background: Limited data is available on the use of a polyester graft limb with a helical stent configuration deployed in the external iliac artery (EIA) during endovascular aneurysm repair (EVAR), so we prospectively analyzed the efficacy of the Zenith Spiral-Z limb deployed in the EIA.

Methods and results: Patients undergoing EVAR using a Zenith stent-graft and Spiral-Z limb deployed in the EIA were prospectively registered in 24 Japanese institutions from June 2017 to November 2017. In total, 65 patients (74 limbs) (mean age: 77.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!