A method for extracting the dark-field signal in propagation-based phase-contrast imaging is proposed. In the case of objects consisting predominantly of a single material, or several different materials with similar ratios of the real decrement to the imaginary part of the complex refractive index, the proposed method requires a single image for extraction of the dark-field signal in two-dimensional projection imaging. In the case of three-dimensional tomographic imaging, the method needs only one image to be collected at each projection angle. Initial examples using simulated and experimental data indicate that this method can improve visualization of small sharp features inside a larger object, e.g. the visualization of microcalcifications in propagation-based x-ray breast cancer imaging. It is suggested that the proposed approach may be useful in other forms of biomedical imaging, where it can help one to obtain additional small-angle scattering information without increasing the radiation dose to the sample.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/abac9dDOI Listing

Publication Analysis

Top Keywords

dark-field signal
12
propagation-based phase-contrast
8
phase-contrast imaging
8
imaging method
8
imaging
6
signal extraction
4
extraction propagation-based
4
method
4
method extracting
4
extracting dark-field
4

Similar Publications

Dark-Field Absorbance Circular Dichroism of Oriented Chiral Thin Films.

J Phys Chem Lett

January 2025

Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States.

Dark-field and confocal approaches to circular dichroism (CD) spectroscopy of uniaxial thin films examine the relationship between symmetry and incoherence in the nonreciprocal CD response, or the component that is antisymmetric about the light propagation direction. Modifying a conventional CD spectrometer for low-angle scattering detection isolates incoherent contributions to nonreciprocal CD of drop-cast thin films, boasting 5-to-10-fold enhancements in CD dissymmetry parameters. Conversely, confocal detection suppresses the nonreciprocal CD response.

View Article and Find Full Text PDF

Comparison of dark-field chest radiography and CT for the assessment of COVID-19 pneumonia.

Front Radiol

January 2025

Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany.

Background: Dark-field chest radiography allows the assessment of the structural integrity of the alveoli by exploiting the wave properties of x-rays.

Purpose: To compare the qualitative and quantitative features of dark-field chest radiography in patients with COVID-19 pneumonia with conventional CT imaging.

Materials And Methods: In this prospective study conducted from May 2020 to December 2020, patients aged at least 18 years who underwent chest CT for clinically suspected COVID-19 infection were screened for participation.

View Article and Find Full Text PDF

A key contribution to X-ray dark-field (XDF) contrast is the diffusion of X-rays by sample structures smaller than the imaging system's spatial resolution; this is related to position-dependent small-angle X-ray scattering. However, some experimental XDF techniques have reported that XDF contrast is also generated by resolvable sample edges. Speckle-based X-ray imaging (SBXI) extracts the XDF by analyzing sample-imposed changes to a reference speckle pattern's visibility.

View Article and Find Full Text PDF

Due to the growing interest in X-ray phase contrast imaging (XPCI), the development of XPCI simulators has become an active field of research. Efficient computer simulations are a prime tool for optimizing the XPCI setup and acquisition process. In addition to phase contrast, modern XPCI setups provide insight into the unresolvable sample micro structure distribution through the dark field signal.

View Article and Find Full Text PDF

Background: X-ray grating-based dark-field imaging can sense the small angle scattering caused by object's micro-structures. This technique is sensitive to the porous microstructure of lung alveoli and has the potential to detect lung diseases at an early stage. Up to now, a human-scale dark-field CT (DF-CT) prototype has been built for lung imaging.

View Article and Find Full Text PDF