Potential approaches for abbreviated knee MRI, including prospective acceleration with deep learning, have achieved limited clinical implementation. The objective of this study was to evaluate the interreader agreement between conventional knee MRI and a 5-minute 3D quantitative double-echo steady-state (qDESS) sequence with automatic T2 mapping and deep learning super-resolutionaugmentation and to compare the diagnostic performance of the two methods regarding findings from arthroscopic surgery. Fifty-one patients with knee pain underwent knee MRI that included an additional 3D qDESS sequence with automatic T2 mapping. Fourier interpolation was followed by prospective deep learning super resolution to enhance qDESS slice resolution twofold. A musculoskeletal radiologist and a radiology resident performed independent retrospective evaluations of articular cartilage, menisci, ligaments, bones, extensor mechanism, and synovium using conventional MRI. Following a 2-month washout period, readers reviewed qDESS images alone followed by qDESS with the automatic T2 maps. Interreader agreement between conventional MRI and qDESS was computed using percentage agreement and Cohen kappa. The sensitivity and specificity of conventional MRI, qDESS alone, and qDESS plus T2 mapping were compared with arthroscopic findings using exact McNemar tests. Conventional MRI and qDESS showed 92% agreement in evaluating all tissues. Kappa was 0.79 (95% CI, 0.76-0.81) across all imaging findings. In 43 patients who underwent arthroscopy, sensitivity and specificity were not significantly different ( = .23 to > .99) between conventional MRI (sensitivity, 58-93%; specificity, 27-87%) and qDESS alone (sensitivity, 54-90%; specificity, 23-91%) for cartilage, menisci, ligaments, and synovium. For grade 1 cartilage lesions, sensitivity and specificity were 33% and 56%, respectively, for conventional MRI; 23% and 53% for qDESS ( = .81); and 46% and 39% for qDESS with T2 mapping ( = .80). For grade 2A lesions, values were 27% and 53% for conventional MRI, 26% and 52% for qDESS ( = .02), and 58% and 40% for qDESS with T2 mapping ( < .001). The qDESS method prospectively augmented with deep learning showed strong interreader agreement with conventional knee MRI and near-equivalent diagnostic performance regarding arthroscopy. The ability of qDESS to automatically generate T2 maps increases sensitivity for cartilage abnormalities. Using prospective artificial intelligence to enhance qDESS image quality may facilitate an abbreviated knee MRI protocol while generating quantitative T2 maps.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8862596PMC
http://dx.doi.org/10.2214/AJR.20.24172DOI Listing

Publication Analysis

Top Keywords

conventional mri
28
knee mri
24
qdess
17
deep learning
16
mri
13
interreader agreement
12
agreement conventional
12
mri qdess
12
sensitivity specificity
12
qdess mapping
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!