Mesh was a promising, minimally invasive, and 'gold standard' treatment for urinary stress incontinence. Time has shown that complications from these devices can happen early, or even several years, after mesh placement and can be catastrophic. Pain, erosion, voiding dysfunction, infection, recurrent UTIs [urinary tract infections (UTIs)], fistulae, organ perforation, bleeding, vaginal scarring, neuromuscular alterations, LUTS (lower urinary tract symptoms), bowel complications and even immune disorders have been linked to mesh. Various tools, such as imaging, endoscopic and functional studies, are available for diagnosis of mesh complications. Since the spectrum of complications is wide, involvement of other specialties is usually beneficial in the diagnosis and management of these complications. There is still much to learn on the accuracy and utility of diagnostic studies in each type of complication. Evidence on the best diagnostic and treatment pathways for these complications is scarce but continuously growing as information is being reported, and we continue to gain expertise in dealing with patients affected by mesh. Treatment options include conservative and medical management initially and then open or minimally invasive surgical procedure approaches. This article will describe diagnostic and treatment pathways for mesh complications.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7378717 | PMC |
http://dx.doi.org/10.1177/1756287220942993 | DOI Listing |
Eur J Obstet Gynecol Reprod Biol
January 2025
Department of Obstetrics and Gynaecology, Key Laboratory of Birth Defects and Related Diseases of Women and Children of MOE, West China Second University Hospital, Sichuan University, Chengdu, Sichuan Province, China. Electronic address:
As an important tool for the surgical treatment of pelvic floor dysfunction, the safety of mesh must be guaranteed. Although the short-term curative effect of most synthetic mesh is satisfactory, complications often occur due to its material. Planting stem cells on mesh through specific methods may resolve the problems of mesh with poor biocompatibility or an uncontrollable rate o degradation.
View Article and Find Full Text PDFDis Colon Rectum
January 2025
Department of Surgery, Division of Colorectal Surgery, The Royal Brisbane and Women's Hospital, Brisbane, Queensland, Australia.
Background: Minimally invasive ventral rectopexy has widely become the preferred prolapse procedure. However there have been recent concerns regarding the safety of permanent synthetic mesh in the pelvis. Biologic grafts have also been commonly used as an alternative prosthesis, but data on their safety and the longevity of the prolapse repair have been lacking.
View Article and Find Full Text PDFEur J Obstet Gynecol Reprod Biol
January 2025
Acıbadem Kartal Hospital, Clinics of Obstetrics and Gynecology, Pelvic Floor and Cosmetic Gynecology Association (PET-KOZ), Istanbul, Turkey.
Objectives: Mid-urethral sling (MUS) insertion is the gold standard approach to treat stress urinary incontinence (SUI) and adaptable single-incision mini-slings (SIMSs) aim to reduce complications. A previous study of our team has found that SIMSs were comparable to transobturator slings in cure rates after 24 months of follow-up. This study aims to compare the rates of cure, complications and re-intervention of both slings over a long-term follow-up of 5 years.
View Article and Find Full Text PDFIntroduction: Iatrogenic injury to the ilioinguinal nerve and its branches during anterior inguinal hernia repair is a cause of chronic inguinal pain in up to 12 % of patients undergoing this operation. The risk of nerve injury is high, given the nerves' relatively small caliber and strictly-confined space through which they pass. In the current report, we describe using a novel fluorescence imaging system developed to detect nerve autofluorescence in a 66-year-old man who presented with a left-sided Type II inguinal hernia and underwent inguinal hernioplasty.
View Article and Find Full Text PDFUrogynecology (Phila)
January 2025
Department of Obstetrics and Gynecology, Beth Israel Deaconess Medical Center, Boston, MA.
Importance: Tobacco smoking is linked to poor surgical outcomes, leading many physicians to avoid synthetic implants like mesh in smokers due to concerns about impaired healing. While long-term outcomes for smokers have been studied, the effect of smoking on 30-day postoperative complications, especially related to surgical mesh, is less understood.
Objectives: This study aimed to quantify the association between tobacco smoking and risk of postoperative infection, readmission, and reoperation within 30 days of minimally invasive apical prolapse repair.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!