We report on a mid-infrared resonant cavity light emitting diode (RCLED) operating at the wavelength of 4.5 µm with a narrow spectral linewidth at room temperature. Compared to a reference LED without a resonant cavity, our RCLED exhibits (85x) higher peak intensity, (13x) higher integrated output power, (16x) narrower spectral linewidth and (7x) superior temperature stability. The device consists of a one-wavelength thick micro-cavity containing an AlInAs/InAsSb quantum well active region sandwiched between two high contrast AlAsSb/GaSb distributed Bragg reflector mirrors, grown lattice-matched on GaSb by molecular beam epitaxy. The high spectral brightness, narrow linewidth and superior temperature stability are attractive features, enabling these devices to be used for detection of NO at 4.5 µm. We show that with only minor adjustments the gases CO (4.2 µm) and CO (4.6 µm) are also readily accessible.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.396928DOI Listing

Publication Analysis

Top Keywords

resonant cavity
12
mid-infrared resonant
8
cavity light
8
light emitting
8
spectral linewidth
8
linewidth superior
8
superior temperature
8
temperature stability
8
emitting diodes
4
diodes operating
4

Similar Publications

Ab initio study on the dynamics and spectroscopy of collective rovibrational polaritons.

J Chem Phys

January 2025

Institute of Chemistry, ELTE Eötvös Loránd University, Pázmány Péter Sétány 1/A, H-1117 Budapest, Hungary.

Accurate rovibrational molecular models are employed to gain insight in high-resolution into the collective effects and intermolecular processes arising when molecules in the gas phase interact with a resonant infrared (IR) radiation mode. An efficient theoretical approach is detailed, and numerical results are presented for the HCl, H2O, and CH4 molecules confined in an IR cavity. It is shown that by employing a rotationally resolved model for the molecules, revealing the various cavity-mediated interactions between the field-free molecular eigenstates, it is possible to obtain a detailed understanding of the physical processes governing the energy level structure, absorption spectra, and dynamic behavior of the confined systems.

View Article and Find Full Text PDF

In this Letter, we propose and experimentally validate a high-fidelity and adaptive forward-phase-based vibration sensing using a Wiener filter (WF). In commercial coherent digital subcarrier multiplexing (DSCM) systems under external cavity lasers (ECLs), frequency-domain pilot tones (FPTs) in subcarrier intervals are employed for dynamic frequency offset estimation (FOE), carrier phase estimation (CPE), and polarization demultiplexing. The phase estimated by the CPE module is processed with the WF to achieve high-fidelity extraction of the vibration-induced phase.

View Article and Find Full Text PDF

Coil embolization of cerebral aneurysms often encounters challenges in achieving complete filling of the aneurysm sac due to complex shapes and hemodynamic factors, frequently resulting in the formation of a residual cavity (RC) at the aneurysm neck. The hemodynamic mechanisms underlying RC formation and growth, however, remain poorly understood. Computational fluid dynamics (CFD) analysis, combined with silent MRA free from contrast agents and metal artifacts, offers a promising approach to elucidate these mechanisms, potentially enhancing the clinical management of cerebral aneurysms post-coiling.

View Article and Find Full Text PDF

Purpose: Correctly classifying uterine fibroids is essential for treatment planning. The objective of this study was to assess the accuracy and reliability of the FIGO classification system in categorizing uterine fibroids via organ-axial T2WI and to further investigate the factors associated with uterine compression.

Methods: A total of 130 patients with ultrasound-confirmed fibroids were prospectively enrolled between March 2023 and May 2024.

View Article and Find Full Text PDF

Objective: This is a case report of a COL4A1 gene mutation which was confirmed by further genetic testing following anomalies observed in prenatal ultrasound and fetal brain magnetic resonance imaging (MRI).

Case Reports: The ultrasound examination of the patient revealed a mass in fetal left intracranial cavity. Repeated subsequent MRI detected an evolving mass in the left frontal parietal lobe.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!