AI Article Synopsis

Article Abstract

: [Ga]Ga-DO3A-VS-Cys-Tuna-2 (previously published as [Ga]Ga-DO3A-VS-Cys-S01-GCG) has shown high-affinity specific binding to the glucagon receptor (GCGR) in vitro and in vivo in rats and non-human primates in our previous studies, confirming the suitability of the tracer for drug development applications in humans. The manufacturing process of [Ga]Ga-DO3A-VS-Cys-Tuna-2 was automated for clinical use to meet the radiation safety and good manufacturing practice (GMP) requirements. The automated synthesis platform (Modular-Lab PharmTrace, Eckert & Ziegler, Eurotope, Germany), disposable cassettes for Ga-labeling, and pharmaceutical-grade Ge/Ga generator (GalliaPharm) used in the study were purchased from Eckert & Ziegler. The parameters such as time, temperature, precursor concentration, radical scavenger, buffer concentration, and pH, as well as product purification step, were investigated and optimized. Process optimization was conducted with regard to product quality and quantity, as well as process reproducibility. The active pharmaceutical ingredient starting material DO3A-VS-Cys-Tuna-2 (GMP-grade) was provided by Sanofi Aventis. The reproducible and GMP-compliant automated production of [Ga]Ga-DO3A-VS-Cys-Tuna-2 with on-line documentation was developed. The non-decay-corrected radiochemical yield was 45.2 ± 2.5% ( = 3, process validation) at the end of the synthesis with a labeling synthesis duration of 38 min and a quality controlincluding release procedure of 20 min. The radiochemical purity of the product was 98.9 ± 0.6% ( = 17) with the total amount of the peptide in the preparation of 48 ± 2 µg ( = 3, process validation). Radionuclidic purity, sterility, endotoxin content, residual solvent content, and sterile filter integrity tests met the acceptance criteria. The product was stable at ambient temperature for at least 2 h. The fully automated GMP-compliant manufacturing process was developed and thoroughly validated. The resulting [Ga]Ga-DO3A-VS-Cys-Tuna-2 was used in a clinical study for accurate quantification of GCGR occupancy by a dual anti-diabetic drug in vivo in humans.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7463542PMC
http://dx.doi.org/10.3390/ph13080176DOI Listing

Publication Analysis

Top Keywords

automated gmp-compliant
8
glucagon receptor
8
manufacturing process
8
eckert ziegler
8
process validation
8
process
6
automated
5
gmp-compliant production
4
production [ga]ga-do3a-tuna-2
4
[ga]ga-do3a-tuna-2 pet
4

Similar Publications

The radiotracer [F]JK-PSMA-7, a prostate cancer imaging agent for positron emission tomography (PET), was previously synthesized by indirect radiofluorination using an F-labeled active ester as a prosthetic group, which had to be isolated and purified before it could be linked to the pharmacologically active Lys-urea-Glu motif. Although this procedure could be automated on two-reactor modules like the GE TRACERLab FX2N (FXN) to afford the tracer in modest radiochemical yields (RCY) of 18-25%, it is unsuitable for cassette-based systems with a single reactor. To simplify implementation on an automated synthesis module, the radiosynthesis of [F]JK-PSMA-7 was devised as a one-pot, two-step reaction.

View Article and Find Full Text PDF

Background Aims: The need for large-scale production of mesenchymal stromal cell (MSC)-based cellular therapeutics continues to grow around the globe. Manual cell expansion processes can be highly variable between operators, require significant hands-on time from skilled staff and, because of the large number of open manipulation steps required to produce cells in dose-relevant quantities, be prone to greater risk of contamination relative to automated processes. All of these can increase overall production costs and risks to the patient.

View Article and Find Full Text PDF

Recent studies have revealed the potential of tumor-infiltrating lymphocytes (TILs) to treat solid tumors effectively and safely. However, the translation of TIL therapy for patients is still hampered by non-standardized and laborious manufacturing procedures that are expensive and produce highly variable cellular products. To address these limitations, the CliniMACS Prodigy Tumor Reactive T cell (TRT) Process has been developed.

View Article and Find Full Text PDF

Lead-it-EAZY! GMP-compliant production of [Pb]Pb-PSC-PEG-TOC.

EJNMMI Radiopharm Chem

November 2024

Department of Nuclear Medicine, University Hospital Carl Gustav Carus, Technical University Dresden, Fetscherstr. 74, 01307, Dresden, Germany.

Background: Recently, radiotheranostics comprising the true matched radionuclide pair Pb could serve as real dosimetric planning utility using Pb-radiolabelled pharmaceuticals before therapy with Pb-radiolabelled counterparts. Pb might act as the missing radionuclide therapy between standard β therapies (e.g.

View Article and Find Full Text PDF

In nuclear medicine, molecular imaging of the tumor microenvironment using radiopharmaceuticals (RPs) targeting cancer-associated fibroblasts is gaining significant interest. Among these RPs, [Ga]Ga-FAPI-46 for positron emission tomography (PET) imaging is frequently used in clinical research protocols. To ensure that the production of this RP complies with good manufacturing practices, process automation is widely adopted.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!