A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Accuracy of the clinical pulmonary infection score to differentiate ventilator-associated tracheobronchitis from ventilator-associated pneumonia. | LitMetric

Background: Differentiating Ventilator-Associated Tracheobronchitis (VAT) from Ventilator-Associated Pneumonia (VAP) may be challenging for clinicians, yet their management currently differs. In this study, we evaluated the accuracy of the Clinical Pulmonary Infection Score (CPIS) to differentiate VAT and VAP.

Methods: We performed a retrospective analysis based on the data from 2 independent prospective cohorts. Patients of the TAVeM database with a diagnosis of VAT (n = 320) or VAP (n = 369) were included in the derivation cohort. Patients admitted to the Intensive Care Centre of Lille University Hospital between January 1, 2016 and December 31, 2017 who had a diagnosis of VAT (n = 70) or VAP (n = 139) were included in the validation cohort. The accuracy of the CPIS to differentiate VAT from VAP was assessed within the 2 cohorts by calculating sensitivity and specificity values, establishing the ROC curves and choosing the best threshold according to the Youden index.

Results: The areas under ROC curves of CPIS to differentiate VAT from VAP were calculated at 0.76 (95% CI [0.72-0.79]) in the derivation cohort and 0.67 (95% CI [0.6-0.75]) in the validation cohort. A CPIS value ≥ 7 was associated with the highest Youden index in both cohorts. With this cut-off, sensitivity and specificity were respectively found at 0.51 and 0.88 in the derivation cohort, and at 0.45 and 0.89 in the validation cohort.

Conclusions: A CPIS value ≥ 7 reproducibly allowed to differentiate VAT from VAP with high specificity and PPV and moderate sensitivity and NPV in our derivation and validation cohorts.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7396887PMC
http://dx.doi.org/10.1186/s13613-020-00721-4DOI Listing

Publication Analysis

Top Keywords

differentiate vat
16
cpis differentiate
12
derivation cohort
12
vat vap
12
accuracy clinical
8
clinical pulmonary
8
pulmonary infection
8
infection score
8
ventilator-associated tracheobronchitis
8
ventilator-associated pneumonia
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!