A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Change in Carotid Blood Flow and Carotid Corrected Flow Time Assessed by Novice Sonologists Fails to Determine Fluid Responsiveness in Spontaneously Breathing Intensive Care Unit Patients. | LitMetric

Measurement of carotid blood flow (CBF) and corrected carotid flow time (ccFT) has been proposed as a non-invasive means of determining fluid responsiveness. We evaluated the ability of CBF and ccFT as assessed by novice sonologists to determine fluid responsiveness in intensive care unit patients. Three novice physician sonologists performed carotid ultrasounds before and after a fluid bolus and calculated changes in CBF and ccFT. Fluid responsiveness was defined as a ≥10% increase in cardiac index as measured using bioreactance. Of 112 participants, 56 (50%) were fluid responders. Changes in CBF and ccFT performed poorly at determining fluid responsiveness: 19 mL/min (area under the receiver operating characteristic curve: 0.58, 95% confidence interval: 0.47-0.68) and 6 ms (0.59, 0.46-0.65) respectively. Novice physician sonologists are unable to determine fluid responsiveness using CBF or ccFT. Further research is needed to identify the key limiting factors in using carotid ultrasound to determine fluid responsiveness.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7771259PMC
http://dx.doi.org/10.1016/j.ultrasmedbio.2020.07.001DOI Listing

Publication Analysis

Top Keywords

fluid responsiveness
28
determine fluid
16
cbf ccft
16
fluid
9
carotid blood
8
blood flow
8
flow time
8
assessed novice
8
novice sonologists
8
intensive care
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!