Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
In therapeutic ultrasound using microbubbles, it is essential to drive the microbubbles into the correct type of activity and the correct location to produce the desired biological response. Although passive acoustic mapping (PAM) is capable of locating where microbubble activities are generated, it is well known that microbubbles rapidly move within the ultrasound beam. We propose a technique that can image microbubble movement by estimating their velocities within the focal volume. Microbubbles embedded within a wall-less channel of a tissue-mimicking material were sonicated using 1-MHz focused ultrasound. The acoustic emissions generated by the microbubbles were captured with a linear array (L7-4). PAM with robust Capon beamforming was used to localize the microbubble acoustic emissions. We spectrally analyzed the time trace of each position and isolated the higher harmonics. Microbubble velocity maps were constructed from the position-dependent Doppler shifts at different time points during sonication. Microbubbles moved primarily away from the transducer at velocities on the order of 1 m/s due to primary acoustic radiation forces, producing a time-dependent velocity distribution. We detected microbubble motion both away and toward the receiving array, revealing the influence of acoustic radiation forces and fluid motion due to the ultrasound exposure. High-speed optical images confirmed the acoustically measured microbubble velocities. Doppler PAM enables passive estimation of microbubble motion and may be useful in therapeutic applications, such as drug delivery across the blood-brain barrier, sonoporation, sonothrombolysis, and drug release.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/TUFFC.2020.3011657 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!