A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analysis of the RF Excitation of Endovascular Stents in Small Gap and Overlap Scenarios Using an Electro-Optical E-field Sensor. | LitMetric

Objective: To assess the effect of the electro-magnetic coupling of endovascular stents on their RF heating potential in MRI.

Methods: A custom-built electro-optic E-field probe is used to perform measurements of the scattered E-field at a distance of 2 mm to stent samples with submillimeter resolution. Various combinations of stent lengths are measured at 124 MHz (3T MRI Larmor frequency) with varying gap and overlap between the stents, with and without stent coating, and with distilled water and saline solution as surrounding media. The results are compared to theoretically derived E-field distributions.

Results: At an overlap of 10 mm the E-field pattern of two stents collapses to a single dipole indicating excellent coupling between the stents. E-field intensities substantially increase/decrease up to 5-fold/2.5-fold if the total length of the two combined stents is closer/further away from the resonance length of the single stents. Stent coating and conductivity of the surrounding medium strongly influence the E-field patterns of overlapping stents. Measured and calculated E-field patterns are in good agreement.

Conclusion: Electro-optic E-field measurements are a valuable tool for RF safety assessments in both single as well as coupled stents.

Significance: RF induced heating of single stents during MRI has been extensively studied. However, in clinical practice often two or more stents are implanted in close proximity which can substantially change the pattern of the scattered electric fields and the localization and intensity of hot spots. In this study a detailed assessment of the coupling of stents during RF excitation is given.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TBME.2020.3009869DOI Listing

Publication Analysis

Top Keywords

stents
11
e-field
9
endovascular stents
8
gap overlap
8
electro-optic e-field
8
stents stent
8
stent coating
8
coupling stents
8
single stents
8
e-field patterns
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!