Introduction: Priapism is defined as a persistent tumescence or erection of the penis not associated to sexual desire and/or stimulation. Idiopathic recurrent priapism may also occasionally follow treatment of veno-occlusive priapism and represents a diagnostic and therapeutic challenge.

Case Presentation: We report a single case of non-ischemic priapism that resulted after distal shunting procedure for severe and prolonged ischemic priapism and yet occurred without evidence of a cavernosal-sinusoidal fistula that was successfully treated with a bilateral selective arterial embolization. Our protocol of delayed inflatable penile prosthesis placement after a vacuum erectile device program was implemented.

Conclusions: The continuing use of a vacuum erectile device represented a bridge and an adjuvant therapy useful to facilitate later prosthesis placement. Anatomical and functional outcomes were optimal. No postoperative complaints or complications were reported.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7292072PMC
http://dx.doi.org/10.1002/iju5.12019DOI Listing

Publication Analysis

Top Keywords

prosthesis placement
12
non-ischemic priapism
8
ischemic priapism
8
selective arterial
8
arterial embolization
8
delayed inflatable
8
inflatable penile
8
penile prosthesis
8
single case
8
vacuum erectile
8

Similar Publications

It is important to be aware of the indications, surgical procedure selection, and associated complications. This chapter focuses on basic screw placement techniques, emphasizing on safety with each anchor placement. Familiarity with managing surgical accidents is also important.

View Article and Find Full Text PDF

Long-term Double-J stenting is superior to short-term Single-J stenting in kidney transplantation.

PLoS One

January 2025

Division of Hepatobiliary and Transplantation Surgery, Department of Surgery, Erasmus MC Transplant Institute, University Medical Center Rotterdam, Rotterdam, The Netherlands.

Background And Objectives: Urological complications after kidney transplantation, due to the ureteroneocystostomy, are associated with significant morbidity, prolonged hospital stay and even mortality. Ureteral stents can minimize the number of complications but are not consistently used, as previous studies were retrospective in nature. We aim to prospectively determine the most effective stenting approach.

View Article and Find Full Text PDF

Atlantoaxial dislocation (AAD) is a serious condition in which the first two cervical vertebrae lose their anatomical position and stability. This may lead to neurological complications, including death. The treatment of AAD remains controversial, and posterior instrumentation with pedicle screw placement is one of the commonly used methods.

View Article and Find Full Text PDF

Berlin Heart EXCOR sVAD implantation technique for neonates and infants with functionally univentricular ductal-dependent systemic circulation.

Multimed Man Cardiothorac Surg

January 2025

Congenital Heart Center, Division of Cardiovascular Surgery, Department of Surgery, University of Florida, Gainesville, FL, USA.

The Berlin Heart EXCOR is a pulsatile paracorporeal ventricular assist device (VAD) for neonates, infants, children and adults with congenital or acquired severe ventricular dysfunction. Berlin Heart EXCOR VADs are routinely used as either a bridge to a cardiac transplantation, or occasionally as a bridge to ventricular recovery. Our programmatic philosophy is to bridge neonates and infants with functionally univentricular ductal-dependent systemic circulation or functionally univentricular ductal-dependent pulmonary circulation who are at high risk for staged palliation because of important cardiac risk factors with a single-ventricle VAD (sVAD) as a bridge to a cardiac transplant.

View Article and Find Full Text PDF

Cannulated screws have significant advantages, including ease of insertion and increased accuracy, during fracture fixation. Unraveling of screw threads is an uncommon complication related to cannulated screws. This single-institution case series aims to highlight four cases of unraveling of cannulated screw threads during the fixation of medial epicondyle humerus fractures in adolescents.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!