We describe 2 cases of pseudotumors induced by an unusual size of polyethylene wear particle after metal-on-polyethylene total hip arthroplasty (MoP THA). The supra-macroparticles of size >100 μm originated from a polyethylene liner with relatively small cup anteversion, potentially leading to excessive loading and increased wear of the anterior edge of the polyethylene liner. Histopathology showed a foreign-body reaction to the polyethylene particles without an adverse reaction to metal debris and with no severe signs of corrosion at the head-neck junction, which have been noted in past reports of pseudotumors in MoP THA. It has been suggested that the large polyethylene wear particles might be the cause of pseudotumor formation in MoP THA.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7387676 | PMC |
http://dx.doi.org/10.1016/j.artd.2020.06.006 | DOI Listing |
J Orthop Case Rep
December 2024
Department of Orthopaedics, AIIMS Raebareli, Raebareli, Uttar Pradesh, India.
Introduction: Metallosis, characterized by the collection of metallic debris in periarticular tissues, is primarily associated with metal-on-metal bearings in hip arthroplasty. This report presents a rare case of metallosis after metal-on-polyethylene (MoP) total hip arthroplasty (THA), highlighting diagnostic challenges and management strategies. Metallosis following MoP arthroplasty is extremely rare, with only a limited number of documented cases in the literature.
View Article and Find Full Text PDFCureus
May 2024
Department of Orthopaedic Surgery, Jawaharlal Nehru Medical College, Wardha, IND.
Soft tissue inflammatory responses to metal debris from prostheses, categorised as adverse reactions to metal debris (ARMD), are frequent complications of total hip arthroplasty (THA) and often result in implant failure. Introducing modular implant designs in modern orthopaedics has brought benefits to total hip replacements but has also increased patients' susceptibility to corrosion-related risks. ARMD can develop from various metal articulating surfaces, including ceramic-on-polyethylene (CoP), ceramic-on-ceramic (CoC), metal-on-metal (MoM), and metal-on-polyethylene (MoP) configurations.
View Article and Find Full Text PDFBone Joint J
March 2024
Department of Orthopaedic Surgery, Copenhagen University Hospital, Hvidovre, Denmark.
Heliyon
December 2023
Division of Agronomy, ICAR-Indian Agricultural Research Institute (IARI) New Delhi, India.
Increasing complexity in crop nutrient requirement in intensive crop production systems needs alternate multi-nutrient sources. Polyhalite (POLY-4) which contains 14% KO along withcalcium (17% CaO), magnesium (6% MgO), and sulfur (19% S) can be a possible recourse in this regard. In maize-wheat systems, it was evaluated for productivity, profitability, nutrient usage, and nutrient use efficiency under Indo-Gangetic plain (IGP) zones for consecutive two years (2018-19 and 2019-20).
View Article and Find Full Text PDFClin Orthop Relat Res
July 2024
Department of Orthopedics, Martini Hospital, Groningen, the Netherlands.
Background: Pseudotumor formation is a well-known complication in metal-on-metal (MoM) THA. Pseudotumors combined with elevated serum ion levels and complaints from patients can lead to high revision rates. Long-term (> 10 years) results obtained from randomized trials comparing large-head MoM THA and conventional metal-on-polyethylene (MoP) THA are lacking regarding revision and survival rates, pseudotumor formation, functional outcomes, and serum ion levels.