Purpose: The authors describe an original technique for treating multiple subretinal perfluorocarbon liquid (PFCL) bubbles complicating previous surgery for rhegmatogenous retinal detachment.

Methods: To facilitate the induction of macular redetachment and peripheral displacement of the PFCL bubbles, we performed the subretinal injection of filtered air in addition to balanced salt solution. In this setting, the action of the PFCL in the vitreous cavity, combined with globe manipulation, allowed bubbles' displacement and full aspiration.

Results: A 57-year-old man had a history of repeated pars plana vitrectomies for recalcitrant rhegmatogenous retinal detachment, the latter leading to multiple subretinal PFCL bubbles retained at the posterior pole. The described technique was performed 8 weeks after the last pars plana vitrectomy. A complete flattening of the macular region was obtained with visual improvement.

Conclusion: Direct injection of air into the subretinal space may represent an effective strategy to help the surgical management of multiple retained PFCL bubbles.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9213074PMC
http://dx.doi.org/10.1097/ICB.0000000000001023DOI Listing

Publication Analysis

Top Keywords

pfcl bubbles
16
subretinal perfluorocarbon
8
perfluorocarbon liquid
8
bubbles complicating
8
retinal detachment
8
multiple subretinal
8
rhegmatogenous retinal
8
pars plana
8
bubbles
5
pfcl
5

Similar Publications

Purpose: To develop a simple tool to remove retained submacular perfluorocarbon liquid bubbles (R-PFCL) and to inject recombinant tissue plasminogen activator safely in subretinal space in submacular hematomas.

Method: A retrospective, interventional study was performed where a simple homemade micro-viscous fluid control was developed to gain access to subretinal space in a controlled way. The rubber cap of the plunger of a 1-mL syringe was cut; this cut rubber cap of the plunger was fitted inside an empty 1-mL tuberculin syringe, and its end was fitted with the tubings of viscous fluid control of the vitrectomy machine.

View Article and Find Full Text PDF

Purpose: To report the role of perfluorocarbon liquid (PFCL) and passive extrusion for management of large full thickness macular holes (FTMHs).

Methods: A standard pars plana vitrectomy with induction of posterior vitreous detachment was performed for all patients. After internal limiting membrane (ILM) peel, a bubble of perfluorocarbon liquid (PFCL) was injected over the posterior pole and passive extrusion of fluid was performed with a backflush instrument below the PFCL bubble, without touching the FTMH edges, until the FTMH centre was reached.

View Article and Find Full Text PDF

Tuck-in tenon patch graft for giant full-thickness macular holes.

Int J Retina Vitreous

July 2024

Department of Ophthalmology, Farah Hospital Abidjan - Ivory Coast, Abidjan, Côte d'Ivoire.

Purpose: To report the results of using autologous Tenon patch grafts for managing giant full-thickness macular holes (FTMHs) when other alternatives are not applicable.

Methods: The same surgical technique was performed in all three cases. Briefly, a small fragment of Tenon's tissue was collected.

View Article and Find Full Text PDF

Subretinal Foveal PFCL Micro-Droplets Removal "Bubble Inside Bubble" (BIB) Technique Without Intraoperative OCT.

Am J Ophthalmol

February 2024

Ophthalmology Department, University Hospital, Saint-Etienne, France; Ophthalmology Department, Hospital Lariboisiere and Fernand-Widal, Paris, France; Laboratory Biology, Engineering and Imaging for Ophthalmology, BiiO, EA2521, Federative Institute of Research in Sciences and Health Engineering, Faculty of Medicine, Jean Monnet University, Saint-Etienne, France. Electronic address:

View Article and Find Full Text PDF

Purpose: We examine the safe removal of a sticky silicone oil (SO) with an inconspicuous perfluorocarbon liquid (PFCL) layer.

Methods: In the first experiment, we injected PFCL into the SO bubble on the bottom of a transparent container or into the chili oil layer of an immiscible droplet composed of PFCL and chili oil on the posterior retina of a vitrectomized pig eye, in order to release the SO bubble or the chili oil layer from the downward adhesion. In the second experiment, we sucked out the SO layer of an immiscible droplet composed of PFCL and SO on the bottom of a transparent container or on the posterior retina of a vitrectomized pig eye using a fragmatome.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!